10 Specification

Measurement

Measurement range
C06 sensor: 0 .25 to 6 m (10" to 20 ft)
C10 sensor: 0 .35 to 10 m (14" to 32 ft)
Beam angle (@ -3dB, full angle)
C06 sensor: 7°
C10 sensor: 5°
Accuracy
±2 mm (0.08") or 0.2 % of full span (the larger of the two)
Repeatability
±0.2 % of measurement range

Mechanical data

Housing material
Metal parts: Aluminum alloy
Plastic parts: PVDF
Dimensions
Length: 136 mm (5 .3")
Width: 100 mm (3 .9") (excluding glands)
Height: 266 mm (10 .4")
Weight
2 kg (4 .4 lbs)
Cable entry type
Two options:
1/2 in . threaded bore for cable gland, directly on housing:
Supplied with 1 x 1/2 in . NPT cable gland
M20 x 1 .5 threaded bore for cable gland, directly on housing:
Supplied with M20 x 1 .5 cable gland

Electrical data

Terminals
Three connections for wire cross sections of up to 2 .5 mm2 (14
AWG) as connection points for power supply and
communication purposes
Grounding
Internal and external ground terminals are provided for 6 mm2
(10 AWG) wire cross sections
L S T 3 0 0 | C O M PA C T U LT R A S O N I C L E V E L T R A N S M I T T E R | L S T 3 0 0 – E N R E V. E
Power supply
The transmitter operates from 16 to 42 V DC with no load and is
protected against reversed polarity (additional loads enable
operation above 42 V DC) .
During use in Exia zones and in other intrinsically safe
applications, the power supply must not exceed 30 V DC .
Ripple
Max. 2.2 mV RMS over a 500 Ω load as per HART specifications
Load limitations
Total measurement circuit resistance at 4 to 20 mA and HART:
R(kΩ) =
A minimum resistance of 250 Ω is required for HART
communication .
Analog output
Two-Wire output: 4 to 20 mA related to level / volume / flow, full
compensation for temperature effects

Displays (option)

Integrated LCD display (code L7)
Widescreen LCD display, 128 x 64 pixels, 52 .5 x 27 .2 mm (2 .06 x
1 .07 in .) dot matrix
Four keys for device configuration and management
Easy setup for quick commissioning
Customized visualizations which users can select
Totalized and actual value flow indication
Temperature and diagnostics message display, and
configuration settings
Integrated LCD display with TTG operation (code L2)
Same specifications as the integrated LCD display (code L7) An
innovative Through-The-Glass (TTG) keypad which can be used
to activate the device configuration and management menus
without having to remove the transmitter housing cover
TTG keys protected against accidental activation
Voltage supply - Minimum operating voltage (V DC)
22 mA