OPTIONS

8.1

CONNECTIVITY OPTIONS

8.2

OPTIONS IN UPS CABINET

Modifications reserved
GE_UPS_USM_TLE_SUL_M16_M50_2bU_V010.docx
3-ph SNMP/WEB plug-in adapter
SNMP - Simple Network Management Protocol
The 3-ph SNMP/WEB plug-in adapter is an interface to the Ethernet Network, and
provides UPS information via the standard SNMP Protocol (UPS-MIB (RFC-1628);
GE Single MIB; GE Parallel MIB).
The UPS can therefore be managed by a Network Management System (NMS)
or by our applications (for instance GE iUPSGuard or GE Data Protection), which
uses this information to determine the state of the UPS in order to guarantee
safe and orderly shut-down of the server, when needed.
GE iUPSGuard
GE's iUPSGuard is a remote monitoring solution for UPS, providing status
monitoring and alarm notification that supports all GE UPS product lines,
anytime, anywhere.
iUPSGuard provides current and detailed information about UPS operation,
including its configuration, internal alarms and operating conditions over web.
iUPSGuard notifies personnel of critical alarms and events via email or SMS,
allowing a User or GE Service Technician to make timely decisions on critical
conditions.
In addition, comprehensive data collection and analysis improves diagnostics
capability and enhances response time.
Continuous monitoring and ongoing maintenance help ensure maximum
performance of your UPS equipment as it protects business critical
applications.
GE Data Protection
GE Data Protection software can communicate with the UPS over RS-232, USB
or SNMP to receive status information and measurement values of the UPS. In
case of a critical condition (time on battery, remaining battery autonomy time
or low battery) for the Load, the software starts a controlled shut-down.
An enhanced alarm management system provides the possibility to start
applications, send messages, and send e-mails for every upcoming or
disappearing alarm.
eBoost™ Operation Mode
High efficiency operating mode, where the load is supplied directly by utility and
automatically transferred to Inverter if the voltage is out of prescribed tolerances.
IEMi Operation Mode
High efficiency operating mode for RPA installations operating in low load conditions,
where the efficiency is maximized by switching one or more units to a stand-by state,
thereby driving the on-line units towards their higher efficiency operating region.
RPA Kit
Redundant Parallel Architecture
Up to 6 units parallel possible for redundancy or capacity in RPA configuration.
Critical Power
Page 88/91