Figure 121. Configure iSCSI Front-End Ports
4.
To use the embedded REPL port for iSCSI replication, configure the port numbered Slot 3/Port 2 on
each storage controller.
a. Set the Purpose field to Front End.
b. Set the Fault Domain field to the appropriate fault domain.
c. (Optional) Type a descriptive name in the User Alias field.
Figure 122. Configure Embedded iSCSI Ports
5.
To use the embedded MGMT and REPL ports for iSCSI replication or front-end connectivity,
configure the ports numbered Slot 3/Port 1 and Slot 3/Port 2 on each storage controller.
a. Set the Purpose field to Front End.
b. Set the Fault Domain field to the appropriate fault domain.
Set up Storage Center Software