Dell SC4020 Deployment Manual page 133

Storage center
Hide thumbs Also See for SC4020:
Table of Contents

Advertisement

Figure 119. Configure the MGMT and iSCSI Ports
5.
(Optional) Change the preferred physical port for one or more virtual ports.
a. Click Edit Virtual Ports. The wizard displays a list of virtual ports.
b. For each virtual port that you want to modify, select the preferred physical port in the Preferred
Physical Port field.
c. When you are finished, click Apply Changes. The iSCSI tab oepns.
6.
If you do not plan to use an iSCSI port, make sure that the port is not configured.
a. Set the Purpose field to Unknown.
b. Set the Fault Domain field to <none>.
c. (Optional) Type a descriptive name in the User Alias field.
Configure iSCSI Ports in Virtual Port Mode for an SC4020 with iSCSI Front-End Ports
Use the iSCSI tab on the Configure Ports page to create fault domains and configure the iSCSI ports.
About this task
The Startup Wizard displays the iSCSI and SAS tabs for an SC4020 with iSCSI front-end ports.
NOTE: The embedded iSCSI ports can be used for replication to another Storage Center or used for
front‐end connectivity to host servers.
Steps
1.
Click the iSCSI tab.
Set up Storage Center Software