Figure 112. Port Configuration Generated
4.
Click Continue. The page that is displayed depends on whether there are any iSCSI transports in
virtual port mode.
5.
If there are iSCSI transports in virtual port mode, a page is displayed asking for IP address attributes
for the control port of the new iSCSI fault domain.
Figure 113. Configure the Control Port for the iSCSI Fault Domain
a. Enter the IP address, subnet mask, gateway, and port for the control port of the new iSCSI fault
domain. Check the pre‐installation documentation for this address.
b. Click Continue. The Startup Wizard generates the new iSCSI fault domain and the initial port
configuration. After the initial port configuration has been generated, it is automatically validated.
6.
Click Configure Local Ports. The Startup Wizard displays a tab for each transport type (FC, iSCSI, and
SAS).
Set up Storage Center Software
127