Summary of Contents for Dell SCv2080

  • Page 1 Dell Storage Center SCv2080 Storage System Owner’s Manual Regulatory Model: E11J Regulatory Type: E11J001 Get other manuals https://www.bkmanuals.com...
  • Page 2 WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell ™...
  • Page 3: Table Of Contents

    ............10 SCv2080 Storage System Back-Panel Features and Indicators ..............11 SCv2080 Storage Controller Features and Indicators ..........16 SCv2080 Storage System Fan Module Features and Indicators ...............17 SCv2080 Storage System PSU Features and Indicators ......................18 SCv2080 Storage System Drives 2 Replacing SCv2080 Components..............19 ..........................
  • Page 4 ........................... 38 Replacing Rack Rails ......................39 Post-Replacement Procedures ......................39 Start up the Storage System ..............39 Sending Diagnostic Data Using Dell SupportAssist ..................39 Contact Dell Technical Support Services 3 Troubleshooting SCv2080 Components............40 ........................40 Troubleshooting PSUs ......................40 Troubleshooting Fan Modules ......................
  • Page 5: About This Guide

    Preface About this Guide This guide describes how to perform service and maintenance on an SCv2080 storage system. Revision History Document Number: J4580 Revision Date Description March 2015 Initial release Audience The information provided in this Owner’s Manual is intended for use by Dell end users.
  • Page 6 Storage Center via the PowerShell interactive shell, scripts, and PowerShell hosting applications. Help for individual cmdlets is available online. • Dell Storage Client Administrator’s Guide Provides information about the Dell Storage Client and how it can be used to manage a Storage Center. • Dell Enterprise Manager Administrator’s Guide Contains in-depth feature configuration and usage information •...
  • Page 7: About The Scv2080 Storage System

    SCv2080 also supports a single SC180 expansion enclosure. SCv2080 Storage System Hardware The SCv2080 is a 5U storage system that supports up to 84 3.5–inch hot-swappable SAS hard drives installed in a two‐drawer, three‐row, 14‐column configuration.
  • Page 8: Scv2080 Storage System Front-Panel Features And Indicators

    SCv2080 Storage System Front-Panel Features and Indicators The SCv2080 front panel shows the storage system chassis and power status. Figure 1. SCv2080 Front-Panel Features and Indicators Item Name Panel Description Drawer-specific Locks the drawer shut using a Torx T20 anti-tamper locks...
  • Page 9 2 NOTE: Both drawer fault LEDs (and all contained DDIC LEDs) will flash when the storage system indicator is set to On in Storage Client. About the SCv2080 Storage System Get other manuals https://www.bkmanuals.com...
  • Page 10: Scv2080 Storage System Back-Panel Features And Indicators

    SCv2080 Storage System Back-Panel Features and Indicators The back panel shows power, connectivity, and fault indicators. Figure 2. SCv2080 Back-Panel Features and Indicators Item Name Icon Description Optional cable — Locations for optional cable retention brackets. retention positions Storage controller —...
  • Page 11: Scv2080 Storage Controller Features And Indicators

    Controls power for the storage system. There is one switch for each power supply. SCv2080 Storage Controller Features and Indicators The SCv2080 includes two storage controllers in two interface slots. The storage controllers support Fibre Channel, iSCSI, or SAS front-end ports. SCv2080 Storage Controller with Fibre Channel Front-End Ports Features and indictors on a storage controller with Fibre Channel front-end ports.
  • Page 12 • Blinking yellow: 8 Gbps activity • Blinking amber and yellow: Beacon • All blinking (simultaneous): Firmware initialized • All blinking (alternating): Firmware fault Mini-SAS port B Back-end expansion port B About the SCv2080 Storage System Get other manuals https://www.bkmanuals.com...
  • Page 13 SCv2080 Storage Controller with iSCSI Front-End Ports Features and indictors on a storage controller with iSCSI front-end ports. Figure 5. SCv2080 Storage Controller with Four 1 GbE iSCSI Front-End Ports Figure 6. SCv2080 Storage Controller with Two 10 GbE iSCSI Front-End Ports...
  • Page 14 • Off: No power with two LEDs per port • Steady Amber: Link • Blinking Green: Activity Mini-SAS port B Back-end expansion port B Mini-SAS port A Back-end expansion port A About the SCv2080 Storage System Get other manuals https://www.bkmanuals.com...
  • Page 15 SCv2080 Storage Controller with SAS Front-End Ports Features and indictors on a storage controller with SAS front-end ports. Figure 7. SCv2080 Storage Controller with Four 12 Gb SAS Front-End Ports Item Control/Feature Icon Description Battery status indicator • Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat •...
  • Page 16: Scv2080 Storage System Fan Module Features And Indicators

    Back-end expansion port B Mini-SAS port A Back-end expansion port A SCv2080 Storage System Fan Module Features and Indicators SCv2080 storage systems include five fan modules in five interface slots. Figure 8. SCv2080 Fan Module Features and Indicators Item Control/...
  • Page 17: Scv2080 Storage System Psu Features And Indicators

    Amber — Loss of communication with the fan module, or reported fan speed is out of tolerance SCv2080 Storage System PSU Features and Indicators SCv2080 storage systems include two Power Supply Units (PSUs) in two interface slots. Figure 9. SCv2080 PSU Features and Indicators Item...
  • Page 18: Scv2080 Storage System Drives

    SCv2080 Storage System Drives Dell Enterprise hard disk drives (HDDs) and Enterprise Solid-State Drives (eSSDs) are the only drives that can be installed in an SCv2080 storage system. If a non-Dell Enterprise drive is installed, Storage Center prevents the drive from being managed.
  • Page 19: Replacing Scv2080 Components

    Always follow these safety precautions to avoid injury and damage to Storage Center equipment. If equipment described in the document is used in a manner not specified by Dell, the protection provided by the equipment may be impaired. For your safety and protection, observe the rules described in the following sections.
  • Page 20: Electrical Safety Precautions

    WARNING: Disconnect power from the storage system when removing or installing components that are not hot-swappable. When disconnecting power, first power down the storage system using the Dell Storage Client and then unplug the power cords from all the power supplies in the storage system.
  • Page 21: Pre-Replacement Procedures

    Shutting Down a Storage Controller If you are replacing a storage controller, use the Dell Storage Client to shut down the storage controller. About this task If the storage system has two storage controllers, shutting down one storage controller causes the Storage Center to fail over to the other storage controller.
  • Page 22: Shutting Down The Storage System

    Shutting Down the Storage System If you are replacing the storage system chassis or rack rails, use the Dell Storage Client to shut down the storage system. About this task CAUTION: Shutting down the storage system results in a system outage.
  • Page 23: Replacing A Psu

    Prerequisites Use SupportAssist to send diagnostic data to Dell Technical Support Services. Contact Dell Technical Support Services to let them know that you are performing a repair. About this task You can replace power supply units one at a time without shutting down the storage system.
  • Page 24 Connect the power cable to the power supply unit and make sure the cable is plugged into a power outlet. Secure the power cable using the clip. Figure 14. Securing the Power Cable Press the power switch to turn on the PSU. Replacing SCv2080 Components Get other manuals https://www.bkmanuals.com...
  • Page 25: Replacing Cooling Fan Modules

    When the PSU is functioning properly, the Power OK indicator turns green and the PSU fault and AC fault indicators are off. In the Dell Storage Client, make sure that the replacement PSU is recognized and shown as up and running.
  • Page 26: Replacing A Cooling Fan Module

    Prerequisites Use SupportAssist to send diagnostic data to Dell Technical Support Services. Contact Dell Technical Support Services to let them know that you are performing a repair. About this task You can replace cooling fan modules one at a time without shutting down the storage system.
  • Page 27 Battery fault and Fan fault LEDs are off. In addition, the cooling fan status indicator turns green in the Dell Storage Client. In the Dell Storage Client, make sure that the replacement fan module is recognized and shown as up and running.
  • Page 28: Replacing Hard Drives

    The drive slots are numbered 1–42 in the top drawer and 43–84 in the bottom drawer. Dell Storage Client identifies drives as XX-YY, where XX is the number of the unit ID of the storage system, and YY is the drive position inside the storage system.
  • Page 29: Replacing A Hard Drive

    Hard drives can be replaced one at a time without shutting down the storage system. Steps Find the SCv2080 and drawer containing the failed drive. The drawer fault LED will be lit. CAUTION: Before opening a drawer, ensure that the Dell Storage Client does not display a temperature warning.
  • Page 30 Drawer latches (2 per drawer) Drawer (2 per chassis) CAUTION: If the SCv2080 operates for too long (depending on altitude) with drive drawers open, the enclosure can overheat, causing potential drive failure and data loss. Such use may invalidate the warranty.
  • Page 31 28 (one full, front row in the top drawer and one full, front row in the bottom drawer), the number of populated rows between drawers must not differ by more than one. Populate the rows from the front to the rear of the enclosure. Replacing SCv2080 Components Get other manuals https://www.bkmanuals.com...
  • Page 32: Replacing The Storage Controller Battery

    Let go of the releases and push the drawer the rest of the way in until it clicks shut. In the Dell Storage Client, make sure that the replacement hard drive is recognized and shown as up and running. If the Dell Storage Client informs you that there are unassigned disks, see the Dell Storage Client Administrator’s Guide for instructions on managing unassigned disks.
  • Page 33: Replacing A Storage Controller

    NOTE: Do not return the storage controller battery with the failed storage controller. A new battery is not included with a replacement storage controller. Identify the Failed Storage Controller To determine which storage controller failed, use the Dell Storage Client . Click the Hardware tab. In the Hardware tab navigation pane, select the Storage Center.
  • Page 34 Click I/O Modules. The status of each storage controller is displayed in the I/O Modules tab. Select the failed storage controller to display its location in the IO Module View tab. Figure 25. Rear View of the Enclosure Showing the Failed Storage Controller Replacing SCv2080 Components Get other manuals https://www.bkmanuals.com...
  • Page 35: Replace A Single Storage Controller

    Replace a Single Storage Controller Use this procedure to replace a single failed storage controller. Prerequisites Use SupportAssist to send diagnostic data to Dell Technical Support Services. Shut down the storage controller using the Dell Storage Client. About this task Storage controllers can be replaced one at a time without shutting down the storage system.
  • Page 36: Replace Both Storage Controllers In Succession

    LEDs on the storage controller. After the one‐minute delay, the fans and LEDs turn on as an indication that the storage controller is starting up. 11. In the Dell Storage Client, make sure that the replacement storage controller is recognized and shown as up and running.
  • Page 37 LEDs on the storage controller. After the one‐minute delay, the fans and LEDs turn on as an indication that the storage controller is starting up. 11. In the Dell Storage Client, make sure that the replacement storage controller is recognized and shown as up and running.
  • Page 38: Replace Both Storage Controllers Simultaneously

    Next steps Use SupportAssist to send diagnostic data to Dell Technical Support Services. Replace Both Storage Controllers Simultaneously If you need to replace both storage controllers at the same time, contact Dell Technical Support Services for assistance. Replacing Rack Rails Rack rails are used to install the SCv2080 storage system into a rack.
  • Page 39: Post-Replacement Procedures

    Start up the storage system and storage system. Post-Replacement Procedures After replacing a component in the SCv2080 storage system, start up the storage system if it was previously shut down and use SupportAssist to send diagnostic data to Dell Technical Support Services.
  • Page 40: Troubleshooting Scv2080 Components

    Troubleshooting SCv2080 Components This section contains basic troubleshooting steps for components inside the SCv2080 storage systems. Troubleshooting PSUs Use these steps to troubleshoot Power Supply Units (PSUs). Check the status of the PSU using the Dell Storage Client. Determine the status of the PSU LEDs.
  • Page 41: Troubleshooting Storage Controllers

    Reinstall the DDIC. Make sure the DDIC contacts the backplane. Troubleshooting Storage Controllers Use these steps to troubleshoot storage controllers. Check the status of the storage controller using the Dell Storage Client. Check the pins and reseat the storage controller. a. Remove the storage controller.
  • Page 42: Scv2080 Technical Specifications

    SCv2080 Technical Specifications This section contains technical specifications of the SCv2080 storage system. Technical Specifications The technical specifications of the SCv2080 storage system are displayed in the following tables. Drives SAS hard drives Up to 84 3.5-inch SAS hot-swappable hard drives (6.0 Gbps)
  • Page 43 Power Supplies AC power supply (per power supply) Wattage 2.8 kW Voltage 200–240 VAC (16 A) Heat dissipation 191-147 W Input frequency 50/60 Hz Max input power 1791 VA Input current 7.4 A@241 VAC SCv2080 Technical Specifications Get other manuals https://www.bkmanuals.com...
  • Page 44 –40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C per hour Relative humidity Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Storage 5% to 100% (noncondensing) SCv2080 Technical Specifications Get other manuals https://www.bkmanuals.com...
  • Page 45 NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m to 3000 m (7000 ft to 10,000 ft). Storage –300 to 12,192 m (–1000 to 40,000 ft) Airborne Contaminant Level Class G2 or lower as defined by ISA-S71.04-1985 SCv2080 Technical Specifications Get other manuals https://www.bkmanuals.com...

This manual is also suitable for:

E11j

Table of Contents