Emergency stop devices meet the following classifications:
- PL d (or smaller) according to EN ISO 13849-1
- Category 3 (or smaller) according to EN ISO 13849-1
- SIL 2 (or smaller) according to IEC 61508
Emergency Stop devices have a cross fault monitoring (2-channel connection) or protected
wiring?
It is ensured that resetting of the safety control device alone does not result in a restart of the
drive.
It is ensured that no voltage higher than DC 30 V can occur on the terminals of the control
electronic unit (voltage resistance)
The protection against unexpected restart is set up.
Commissioning:
Functional check of safety function performed?
Wiring of safety components checked?
Acceptance report issued?
Operation:
The machine must be operated only inside the specified limits.
The safety function is checked regularly.