Technical data
9.4 FLIR A300f 25°
P/N: 61201-1003
Rev.: 35207
General description
The main purpose of the housing on the FLIR A300f is to increase the environmental specification of
the standard FLIR A300 to IP66 without affecting any of the features available in the camera itself.
The built-in FLIR A300 camera provides an affordable and accurate temperature measurement solution
for anyone who needs to solve problems that do not call for the highest speed or reaction and who uses
a PC. Due to its composite video output, it is also an excellent choice for thermal image automation ap-
plications, where you can utilize its unique properties such as looking through steam.
Key features:
Encapsulation to IP66.
MPEG-4 streaming.
PoE (Power over Ethernet).
Built-in web server.
General purpose I/O.
100 Mbps Ethernet (100 m cable, wireless, fiber, etc.).
Synchronization through SNTP.
Composite video output.
Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included.
Open and well-described TCP/IP protocol for control and set-up.
16-bit 320 × 240 pixel images at 3 Hz, radiometric.
Typical applications:
Fire prevention, critical vessel monitoring, and power utility asset management
Volume-oriented industrial control (multi-camera installation is possible)
Imaging and optical data
IR resolution
Thermal sensitivity/NETD
Field of view (FOV)
Minimum focus distance
Focal length
Spatial resolution (IFOV)
Lens identification
F-number
Image frequency
Focus
Zoom
Detector data
Detector type
Spectral range
Detector pitch
Detector time constant
Measurement
Object temperature range
Accuracy
#T559794; r. AJ/35709/35709; en-US
320 × 240 pixels
< 0.05°C @ +30°C (+86°F) / 50 mK
25° × 18.8°
0.4 m (1.31 ft.)
18 mm (0.7 in.)
1.36 mrad
Automatic
1.3
30 Hz
Automatic or manual (built in motor)
1–8× continuous, digital, interpolating zooming on
images
Focal plane array (FPA), uncooled
microbolometer
7.5–13 µm
25 µm
Typical 12 ms
–20 to +120°C (–4 to +248°F)
0 to +350°C (+32 to +662°F)
±4°C (±7.2°F) or ±4% of reading
15