Table 2-3 575 V drive ratings, cable sizes and fuse ratings
Max.
cont.
input
IEC
current
Model
3ph
Nom
Class
A
A
07500440
45
50
07500550
62
80
08500630
83
125
08500860
104
160
09501040
166
150
09501310
166
200
10501520
197
250
10501900
218
* These fuses are fast acting.
Table 2-4 690 V drive ratings, cable sizes and fuse ratings
Max.
cont.
input
IEC
current
Model
3ph
Nom
Class
A
A
07600190
20
25
07600240
26
32
07600290
31
40
07600380
39
50
07600440
44
50
07600540
62
80
08600630
83
125
08600860
104
160
09601040
149
150
09601310
171
200
10601500
202
225
10601780
225
250
* These fuses are fast acting.
Refer to Chapter 5.1 Drive technical data on page 88 for maximum fuse rating, maximum
NOTE
cable size and peak currents.
Table 2-5 Protective ground cable ratings
Input phase conductor size
2
≤ 10 mm
2
2
> 10 mm
and ≤ 16 mm
2
2
> 16 mm
and ≤ 35 mm
2
> 35 mm
14
Nominal cable size
Fuse
European
UL
Input Output Input Output
Nom
Class
2
A
mm
50
16
CC,
gG
J or T*
80
25
100
35
gR
HSJ
150
50
150
HSJ
2 x 70
gR
(B2)
175
HSJ
2 x 70
(B2)
gR
250
HSJ
2 x 95
(B2)
Nominal cable size
Fuse
European
UL
Input Output Input Output
Nom
Class
2
A
mm
mm
25
10
10
30
10
10
CC,
35
10
10
gG
J or
50
16
16
T*
50
16
16
80
25
25
100
50
50
gR
HSJ
150
70
70
2 x 50
2 x 35
150
(B2)
(B2)
gR
HSJ
2 x 70
2 x 50
200
(B2)
(B2)
2 x 70
gR
(B2)
2 x 70
250
HSJ
(B2)
2 x 95
gR
(B2)
2
Either 10 mm
or two conductors of the same cross-sectional area as the input
phase conductor
The same cross-sectional area as the input phase conductor
2
16 mm
Half of the cross-sectional area of the input phase conductor
USA
Max.
cont.
output
current
2
AWG
AWG
A
mm
16
4
4
53
25
3
3
73
35
1
1
86
50
1
1
108
2 x 35
2 x 3
125
(B2)
2 x 1
2 x 50
2 x 1
155
(B2)
200
2 x 70
2 x
2 x
(B2)
2/0
2/0
200
Normal Duty
USA
Max.
cont.
output
current
2
AWG
AWG
A
8
8
23
6
6
30
6
6
36
4
4
46
4
4
52
3
3
73
2
2
86
1/0
1/0
108
2 x 1
2 x 3
125
2 x 1/0
2 x 1
155
2 x 2/0 2 x 1/0
172
2 x 3/0 2 x 2/0
197
Minimum ground conductor size
Unidrive M / HS Frame 7 to 10 Power Installation Guide
Normal Duty
Heavy Duty
Nom
Motor
Max.
power
power
cont.
power
@
@
output
575 V
575 V
current
kW
hp
A
45
50
44
55
60
55
75
75
63
90
100
86
110
125
104
110
150
131
130
200
152
150
200
190
Heavy Duty
Nom
Motor
Max.
Nom
power
power
cont.
power
@
@
output
690 V
690 V
current
690 V
kW
hp
A
18.5
25
19
22
30
24
18.5
30
40
29
37
50
38
45
60
44
55
75
54
75
100
63
90
125
86
110
150
104
132
175
131
160
200
150
185
250
178
Issue Number: 5
Nom
Motor
power
@
@
575 V
575 V
kW
hp
30
40
37
50
45
60
55
75
75
100
90
125
110
150
132
200
Motor
power
@
@
690 V
kW
hp
15
20
25
22
30
30
40
37
50
45
60
55
75
75
100
90
125
110
150
132
175
160
200