6.
Wait until the system completes the software update from the USB drive
and the first touch-screen calibration is displayed
7.
Remove the USB drive from the USB port before proceeding to the next
step
8.
Follow the instructions on the display to calibrate the touch screen by
touching the crosshair at five different points. Note: In order to
accurately calibrate the touch screen, it's recommended that the stylus
pen is used
9.
Wait until the system completes the rebooting sequence and the home
screen is displayed
10. Repeat sections 5.1.1 and 5.1.2 to re-calibrate the air pressure
28

3. SPECIFICATIONS

290mm x 212mm x 98mm
Size
(11.4" X 8.3" X 3.9")
Weight
3.1 kg (6.8lbs)
Input Voltage
24VDC
Output Voltage Range
0-24 VDC
Rated Power
15W
Air Input
100 psi (6.9 bars) Max.
Air Output
0-99.9 Psi (6.9 bar)
Pollution Degree
II
Installation Category
I
Indoor Use
Altitude up to 2,000m (6,562ft)
Operating Temperature
0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature
-10˚C to 60˚C (14˚F to 140˚F)
80% for temperature up to 31˚C (87.8˚F) Decreasing
Max. Relative Humidity
linearly to 50% relative humidity at 40˚C (104˚F)
Timer
0.008-99.99 seconds
Cycle Mode
Timed, Interrupt, Teach, Purge
Timing Repeat Tolerance
+/- 0.001%
Cycle Rate
900 cycles/min
Display
Touch Screen, Resitive
Meets or exceed
CE, TUV and NRTL

FEATURES

4.
AIR OUTPUT A
WIFI ANTENNA
TS560R
AIR OUTPUT B
TOUCH
SCREEN
Figure 1.0
POWER
AIR INLET
AIR OUTLET
SWITCH
UNREGULATED
IO PORT
USB PORT
FOOT
GROUNDING
SWITCH
POWER
INTERNET
PORT
INLET
PORT
5