Symbol Definitions - TECHCON SYSTEMS TS550R User Manual

Smart controller for pneumatic valves
Table of Contents

Advertisement

2. SYMBOL DEFINITIONS

Symbol
Description
Run (Activate)
Input Pressure
Pressure Port A&B
Timed mode
Interrupt mode
Teach mode
Purge mode
Dispense
Login/Logout
Run Method
Continous Mode
E-Stop
Remote Server
Off Line
Symbol
Description
Setup
Counter reset
Mac address
Accept change
Pressure calibration
Save
Reset time in Teach
mode
IP address
Cancel
Sequence Mode
Sequence Continous
Mode
Change Password
On line
4
8. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
 No power inputs
Display does
not light up
 Supplied pressure
System will not
actuate
dropped below "Low
Pressure" setting
 Foot switch not plugged
in or improperly
plugged in
 Defective foot switch
 Broken wire or loose
connection inside unit
 Defective solenoid
 Defective PC board
 Insufficient air pressure
System will not
pressurize
 Air hoses not plugged
in
 Regulator defective
 Air bubbles in material
Inconsistent
 Dispense time is too
dispense
low
 Needle clogged
CORRECTION
 Check power cord
connections
 Turn on power
 Increase supplied
pressure
 Check foot switch
connection
 Foot switch needs to be
repaired or replaced
 Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
 Replace solenoid
 Replace PC board
 Increase air supply
pressure
 Check connection
 Replace regulator
 De-air material
 Increase dispense time
 Replace needle
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents