2. SYMBOL DEFINITIONS
Symbol
Description
Run (Activate)
Input Pressure
Pressure Port A&B
Timed mode
Interrupt mode
Teach mode
Purge mode
Dispense
Login/Logout
Run Method
Continous Mode
E-Stop
Remote Server
Off Line
Symbol
Description
Setup
Counter reset
Mac address
Accept change
Pressure calibration
Save
Reset time in Teach
mode
IP address
Cancel
Sequence Mode
Sequence Continous
Mode
Change Password
On line
4
8. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
No power inputs
Display does
not light up
Supplied pressure
System will not
actuate
dropped below "Low
Pressure" setting
Foot switch not plugged
in or improperly
plugged in
Defective foot switch
Broken wire or loose
connection inside unit
Defective solenoid
Defective PC board
Insufficient air pressure
System will not
pressurize
Air hoses not plugged
in
Regulator defective
Air bubbles in material
Inconsistent
Dispense time is too
dispense
low
Needle clogged
CORRECTION
Check power cord
connections
Turn on power
Increase supplied
pressure
Check foot switch
connection
Foot switch needs to be
repaired or replaced
Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
Replace solenoid
Replace PC board
Increase air supply
pressure
Check connection
Replace regulator
De-air material
Increase dispense time
Replace needle
29