Table Of Contents; Safety; Symbol Definitions; Specifications - TECHCON SYSTEMS TS500R User Manual

Multi-purpose digital controller
Hide thumbs Also See for TS500R:
Table of Contents

Advertisement

CONTENTS
1.
Safety ........................................................................... 2
2.
........................................................ 3
3.
Specifications .................................................................. 3
4.
Features ....................................................................... 4
5.
5.1 To Control Pneumatic Valve ......................................... 4
5.2 To Control Spray Valve ............................................... 6
5.3 To Control TS5000 Rotary Pump .................................... 8
5.4 To Control TS5000 Rotary Pump with Encoder Motor............ 9
5.5 Cycle Counter .......................................................... 10
5.6 To Change Pressure Unit Display.................................... 11
5.7 Low Pressure Setting .................................................. 11
5.8 Multiple Shots Setting ................................................ 11
6.
Troubleshooting .............................................................. 12
7.
Maintenance ................................................................... 13
8.
................................................ 13
9.
Warranty ........................................................................ 13
10. I/O Configuration and End of Cycle Switch

SAFETY

1.
1.1 Intended Use:
WARNING: Use of this equipment in ways other than those described in this User
Guide may result in injury to persons or damage to property. Use this equipment
only as described in this User Guide.
OK International cannot be responsible for injuries or damages resulting from
unintended applications of its equipment. Unintended uses may result form taking
the following actions:
• Making changes to equipment that has not been recommended in the User
Guide
• Using incompatible or damaged replacement parts
• Using unapproved accessories or auxiliary equipment
1.2 Safety Precautions:
• Do not operate this unit in excess of maximum ratings/settings
• Always wear appropriate personal protective clothing or apparel
• Use only the following power adaptor models: PSA15R-240P(ZJ)
• The fluid being dispensed may be toxic and/or hazardous. Refer to Material
Safety Data Sheet for proper handling and safety precautions
• Do not smoke or use open flame when flammable materials are being dispensed
• This equipment is for indoor use only
Page Number
............................ 14
2

2. SYMBOL DEFINITIONS

Symbol
Definition
Power On/Off
Cycle Mode
Timer

3. SPECIFICATIONS

254mm x 191mm x 102mm
Size
(10" X 7.5" X 4.0")
Weight
2.6 kg (5.8lbs)
Input Voltage
24VDC
Output Voltage Range
0-24 VDC
Rated Power
15W
Air Input
100 psi (6.9 bars) Max.
Air Output
0-100 Psi (6.9 bar)
Pollution Degree
II
Installation Category
I
Indoor Use
Altitude up to 2,000m (6,562ft)
Operating Temperature
0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature
-10˚C to 60˚C (14˚F to 140˚F)
80% for temperature up to 31˚C (87.8˚F) Decreasing
Max. Relative Humidity
linearly to 50% relative humidity at 40˚C (104˚F)
Timer
0.008-60.000 seconds
Cycle Mode
Timed, Interrupt, Purge
Timing Repeat Tolerance
+/- 0.001%
Cycle Rate
900 cycles/min
LCD
20 X 4 display segments