7. Type: "cd :\iot" then press the "Enter" button
8. Type: "set OKI_IOT_PREFIX=MyPrefix" then press the "Enter" button
22
4. Touch the Check Mark icon to save and exit
5. Press the foot switch to activate the "Timed" dispense cycle.
Alternately, touch the run icon on the display to activate the "Timed"
dispense cycle.
Note: The unit has an "Interrupt" mode feature. In this mode, the
"Timed" dispense cycle can be disrupted if the foot switch is released and
resumed when the Foot Switch is depressed again.
6. Touch the "Interrupt" icon to activate "Interrupt" mode. The icon should
turn to green color.

5.2.5 Teach Mode Setting

In the teach mode, the dispense time will be accumulated as long as the
foot switch is depressed. This is helpful in determining the required
dispense time when the dispense output is known.
1. Touch the "Teach" icon to enter the teach mode
2. Touch the "Time Reset" icon to set timer to zero
3. Press and hold down the foot switch, the dispense time will be accumulated
4. Release the foot switch when the desired amount of fluid has dispensed
5. Touch the "Timed" icon to transfer the accumulated dispense time to
"Timed" mode
6. The unit is now set to repeat this "Timed" cycle
5.2.6 To run in Continous Mode
The controller can be setup to repeat the run continuously.
1. Touch the Setup icon to enter the setup screen