5.
TO CONTROL PNEUMATIC VALVE
CAUTION: A 5-micron filter (TSD800-6) must be installed with the unit to ensure proper
air filtration.
TO AIR SOURCE
1
5
TS570R
Figure 2.0
Items
Description
1
Air Filter
2
Valve (not included)
3
Pressure Pot (not included)
4
Display
5
Power Adapter
6
Foot Switch
5.1 Connecting the Unit: (Refer to Figure 1.0 and 2.0)
1. Connect the power cord, foot switch to the back of the unit.
2. Connect Valve air hose to either Port A or Port B
3. Press the Power switch to turn on the unit.
2
3
4
6
6
Proceed to make changes
Click "OK" button to save
The new parameters will be displayed on the controller
7. SOFTWARE UPGRADE
Note: For future software upgrade, follow the instructions below.
1.
Download the latest software version from Techcon website and copy it to
a blank USB thumb drive. Note: Do not put the software file inside a
folder
2.
Make sure that the unit is turned off
3.
Insert the USB drive to the USB port located in the back of the unit
4.
Turn on the unit
5.
Wait while the system is loading the new software. This process can take
a few minutes
27