With Strike lock mode selected, the auxiliary relay will pulse for the preprogrammed on time, half a second before the gate opens.
Whenever a lock is installed with the system, a separate battery backed up power supply matching the lock load must be installed. Failure to do this
can damage the charger and battery of the control unit.
Below is an example of strike lock mode when standard BT mode is active.
Action
Momentary BT trigger.
Half a second after
the auxiliary relay has
activated.
After the
preprogrammed relay
on time.
Gate reaches open
position.
Momentary BT trigger.
At full closed position.
Auxiliary relay modes.
Strike lock mode.
Gate closed.
0
0.5 sec.
0
1 sec.
Auxiliary relay
No buzzer tone.
activates.
Gate begins
No buzzer tone.
opening.
Auxiliary relay
deactivates and
No buzzer tone.
gate continues
opening.
Gate stops.
No buzzer tone.
Gate begins
No buzzer tone.
closing.
Gate stops.
No buzzer tone.
15
Basic operating
features
Response
ON
Com
OFF
Com
N/C
N/O
N/C
N/O