Magnetic Lock Mode - E.T. Systems Drive 500 User Instructions

500kg slide gate operators. low/high traffic
Hide thumbs Also See for Drive 500:
Table of Contents

Advertisement

Basic operating
features
With Magnetic lock mode selected, the auxiliary relay will activate, half a second before the gate opens and remain activive until half a second after
the gate has closed again.
Whenever a lock is installed with the system, a separate battery backed up power supply matching the lock load must be installed. Failure to do this
can damage the charger and battery of the control unit.
Below is an example of magnetic lock mode when standard BT mode is active.
Action
Momentary BT trigger.
Half a second after
the auxiliary relay has
activated.
Gate reaches open
position.
Momentary BT trigger.
At full closed position.
Half a second after gate
has reached the full
closed position.
Gate closed.
0
0.5 sec.
0
0.5 sec.
Auxiliary relay modes.

Magnetic lock mode.

Auxiliary relay
No buzzer tone.
activates.
Gate begins
No buzzer tone.
opening.
Gate stops.
No buzzer tone.
Gate begins
No buzzer tone.
closing.
Gate stops.
No buzzer tone.
Auxiliary relay
No buzzer tone.
deactivates.
16
Response
ON
Com
OFF
Com
N/C
N/O
N/C
N/O