Basic operating
features
The PED trigger is a higher security option and is used when access to or from the property is limited to exclude motor vehicles.
In the case of no safety beams being installed then the pedestrian auto-close functionality is disallowed for safety.
If the Loop or the BT triggers are activated at any time during the pedestrian routine, the gate will open to the full open position and the pedestrian
transaction is cancelled. The system then reverts to either the Loop or BT trigger mode depending on which was triggered.
There are two ways of activating the "PED" functions on this control card. Either via the hardwired PED input or the PED receiver channel.
Action
Momentary PED trigger.
After buzzer silences.
At previously
programmed
pedestrian opening
distance.
Momentary PED trigger.
After buzzer silences.
At full closed position.
Gate closed.
STOP
"PED" Pedestrian trigger.
(With no safety beams installed)
Buzzer beeps
pre-run
warning.
Gate begins
No buzzer tones.
opening.
Gate stops
and waits for
No buzzer tones.
a pedestrian
trigger to close.
Buzzer beeps
pre-run
warning.
Gate begins
No buzzer tones.
closing.
Gate stops.
No buzzer tones.
12