“Ped” Pedestrian Trigger. - E.T. Systems Drive 500 User Instructions

500kg slide gate operators
Hide thumbs Also See for Drive 500:
Table of Contents

Advertisement

The PED trigger is a higher security op on and is used when access to or from the property is limited to exclude motor vehicles.
If the safety beams are triggered while the gate is closing in pedestrian mode, the gate will only return to the preprogrammed pedestrian open
posi on.
If the Loop or the BT triggers are ac vated at any me during the pedestrian rou ne, the gate will open to the full open posi on and the pedestrian
transac on is cancelled. The system then reverts to either the Loop or BT trigger mode depending on which was triggered.
There are two ways of ac va ng the "PED" func ons on this control card. Either via the hardwired PED input or the PED receiver channel.
Ac on
Momentary PED trigger.
A er buzzer silences.
At previously
programmed
pedestrian opening
distance.
Momentary PED trigger
or safety beam circuit
trigger.
Pedestrian auto-close
mer mes out.
A er buzzer silences.
At full closed posi on.
"PED" Pedestrian trigger.
(With safety beams installed)
Gate closed.
Buzzer beeps
pre-run
warning.
Gate begins
No buzzer tones.
opening.
Gate stops and
the pedestrian
auto-close
No buzzer tones.
mer starts
coun ng down.
Pedestrian
auto-close
No buzzer tones.
mer resets.
Buzzer beeps
pre-run
warning.
Gate begins
No buzzer tones.
closing.
Gate stops.
No buzzer tones.