Wiring Diagram (With Output Groupings Shown) - Renishaw RMI-Q Installation Manual

Radio machine interface
Hide thumbs Also See for RMI-Q:
Table of Contents

Advertisement

RMI-Q installation guide

Wiring diagram (with output groupings shown)

3.2
NOTE: A switch can be added on installation to aid with powering up the RMI-Q when partnering.
!
CAUTION: The power supply 0 V should be terminated at the machine ground (star point).
A negative supply can be used when wired appropriately.
RMI-Q
Turquoise
Turquoise/black
Violet
Violet/black
Green
Green/black
White
Pink
White/red
White/blue
Brown
5 V
Yellow
Driver
Grey
Driver
Orange
Red
12 V to 30 V
Black
0 V
Screen
Green
}
Probe status 1 (SSR)
}
Low battery (SSR)
}
Error (SSR)
Machine start input [P1]
Machine start input [P2]
Machine start input [P3]
Machine start input [P4]
Machine start common
Signal
Probe status 2a
}
(5 V isolated driven skip)
Return
Probe status 2b
See NOTE
}
Power supply (12 V to 30 V)
Machine ground (star point)