Settings
14.Threading device
Check
1. Insert a new # 70 needle.
2. Bring the needle bar to its highest turning position.
3. The threader hook shall go smoothly into the needles eye. See Fig 1 and Fig 2.
Adjustment
1. Loosen the two screws (A) on the back of the threader head (B).
2. Move the white needle thread head (B) so that the threader hook (D) does not touch the needle eys inside
3. Move the silver looking needle thread hook holder (C) so that the threader hook (D) does not touch the
4. Tighten the screws.
NOTE! Both settings are adjusted at the same time
Fig 2
Fig 1
D
D
C
B
A
104 72 79-26