4.
Check the cartridge spindle 'O' seal (fitted in the cover) for signs of damage and
renew if necessary. Fit the spindle 'O' seal and retaining bush into the cover.
5.
Check the cover 'O' seal for signs of damage and renew if necessary.
6.
Follow the procedure detailed in the section "Cartridge renewal": instructions
9 to 15 to re-assemble the shower control.
Plastic Pins
'O' Seal
Cartridge
Retaining Bush
'O' Seal
'O' Seal
Cover 'O' Seal
45
Cover
Cover Retaining Screws