Mira 415 Installation And User Manual page 18

Pressure balanced shower control
Hide thumbs Also See for 415:
Table of Contents

Advertisement

3.
Remove the plaster and brickwork to the required depth to conceal the supply
pipework. Your attention is drawn to the requirements of Byelaw 58 with regard
to "Accessibility of Pipes and Pipe Fittings.
note! Depth must be sufficient to prevent pipe concealing plates fouling on
the plumbing elbows.
4.
Install the hot and cold water supply pipework ensuring that the pipe ends
emerge from the wall surface at 153mm centres, and project from the finished
wall surface by 13mm. Allow for two circular recesses measuring 32mm
diameter x 10mm depth, to accept the two pipework concealing plates.
Backplate
Circular Recess
153mm
18
13mm from Finished
Wall Surface
Concealing Plate

Advertisement

Table of Contents
loading