1.4 Remove the backplate by releasing, anti-clockwise, the two recessed grub
screws which retain the backplate against the brass shower control body, using
the 2.5mm A/F hexagon wrench (supplied).
Grub Screw
1.5 Mark the final position on the finished wall surface using the backplate as a
template.
Mark through the backplate the position of the two holes ensuring that they are
vertically aligned.
1.6 Drill and suitably plug the two marked fixing holes. Secure the backplate to the
wall with the two No. 8 x 1
ensuring that screw head seats into guide ribs.
note! Screws with larger heads will foul the shower control body.
1.7 Thoroughly flush the incoming hot and cold water supplies before final
connection of the shower control (Byelaw 55).
Backplate
/
fixing screws and wallplugs provided, if suitable,