3.2.6 General installation recom-
mendations - Junction box
The junction box should be mounted on a fl at surface (Fig. 47).
Mounting holes to be drilled min. 6.25 mm diameter to avoid
stress at the box from incorrect location.
On mounting ensure cable runs are up to the junction box
(Fig. 47).
Drain hole to be shielded by chassis as shown to provide
as much protection from direct spray and other road debris
(Fig. 47).
Ensure outer insulation of the cable is inside the junction box
by 5 mm minimum (Fig. 48).
3.2 Electrical wiring
Junction box
Cable
Fig. 47
Junction box
Fig. 48
Junction box drain hole
min. 15 mm
Outer insulation cable
33