Safety instructions

This quick start guide to serves as a reminder for
experienced installers. We strongly recommend reading
the full manual before installing the control system.

Controller

W
!
arning
The Uponor system uses 50 Hz, 230 V AC
power. In case of emergency, immediately
disconnect the power.
W
!
arning
Electrical installation and service behind
secured 230 V AC covers must be carried
out under the supervision of a qualified
electrician.
W
!
arning
The transformer module is heavy and might
detach if the controller is held upside down
without the cover on.
C
!
aution
To avoid interference, keep installation/data
cables away from power cables of more than
50 V.
C
!
aution
If communication difficulties exist, Uponor
recommends relocating the antenna to a more
optimal position, and not installing Uponor
radio sources to close to each other (at
least 40 cm apart), for solving exceptional
problems.
C
!
aution
Ensure that each actuator is connected to the
correct channel so that the thermostats are
controlling the correct loops.
N O T E !
Wires between transformer and controller card
needs to be disconnected prior to detaching.
N O T E !
Connect only one actuator for each channel.
Channels 01 and 02 have double outputs (a
and b) for two actuators.
U P O N O R S M AT R I X WAV E · Q U I C K G U I D E
QUICK GUIDE
Thermostat/System device

Thermostatic Head

N O T E !
Registration of at least one thermostat must
be done before registering a system device.
N O T E !
Up to four controllers can be registered to an
interface.
C
!
aution
If more than one controller is available in the
system, register the thermostat as a system
device to the master controller.
C
!
aution
The switches in public the thermostat must
be set before the thermostat is registered.
C
!
aution
The switches, in the public thermostat, must
be set to one of the available functions,
otherwise it cannot be registered.
N O T E !
The thermostat in control of the thermal
heads should not also control under floor
heating. Make notes to make sure
N O T E !
If two thermostatic heads already have been
registered to a channel, register the third to
the next channel in line. If more thermostat
channels are needed they can be added in
thermostat registration mode.
N O T E !
There is no indication showing if a
thermostatic head already is registered to a
channel.
C
!
aution
The thermostatic head must be installed on
a radiator before registering it to a controller.
Because the thermostatic head will perform a
valve stroke calibration, when registered, to
accurately operate the valve on the radiator.