Cooling And Heating Data Sheet In Rated Frequency; Noise Curve - Gree GWH09YC-K6DNA1A Service Manual

Table of Contents

Advertisement

2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5m.

2.5 Noise Curve

45
42
39
36
33
30
25
20
75
60
Compressor frequency(Hz)
8
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
0.8 ~ 1.1
12K
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
2.8 ~ 3.2
12K
45
30
12K
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
12 to 15
65 to 38
11 to 14
64 to 37
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
35 to 63
2 to 5
35 to 65
2 to 5
6 5
6 0
55
50
4 0
15
09K
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
SL
L
ML
M
Indoor fan motor rating speed
Technical Information
Service Manual
Compressor
revolution
(rps)
49
60
Compressor
revolution
(rps)
59
67
MH
H
SH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh12yc-k6dna2aGwh09yc-k6dna2aGwh12yc-k6dna1a