Page 1
Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@gree.com.cn for the electronic version.
Content Operation Notices The Refrigerant......................1 Precautions......................2 Special function and specification................7 Parts’ Name......................10 Screen Operation Guide Buttons on remote controller ................11 Introduction for buttons on remote controller ............11 Replacement of batteries in remote controller............16 Emergency operation ...................16 Maintenance Clean and Maintenance..................17 Malfunction Malfunction analysis ....................19 Installation Notice...
Page 4
Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
Appliance filled with flammable gas R32. Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Precautions Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe Children shall not play with the appliance.
Page 8
Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
Page 10
Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
Special function and specification Anti-freezing function When the unit is conducting cooling under low temperature, the surface of indoor heat exchanger will be frosted; when the temperature of indoor heat exchanger is decreased to below 0°C for a period of time, the outdoor unit will stop operation.
Page 12
Special function and specification Detection of people sensing device Under cooling or heating mode, press “I Sense” button in the remote controller or use APP in mobile phone to enter into “I Sense air supply”, after setting I sense, follow, avoid, surround mode, people sensing device is automatically activated to detect.
Page 13
Special function and specification Auto clean function of indoor heat exchanger Realize auto clean by utilizing sweating, frosting, defrosting and evaporator high temperature. 1. Under the remote controller is off, press “MODE” and “FAN” button at the same time for 5 seconds to start auto clean function, then the unit will display “CL”.
Parts’ Name Indoor Unit Air inlet Filter Air inlet grille Human sense device Panel Air guide louver Air outlet display Power / Temperature Auxiliary heating display (Display content or position may be different from above graphics, please refer to actual products) remote controller NOTICE: Actual product may be different from above graphics, please refer to actual...
Buttons on remote controller Tip: this series has no health and breeze functions. Set fan speed display Battery display Mode display Child lock status display Set temperature display Timer function display Direction display All kinds of function status display ON/OFF button / button cool button heat button...
Page 16
Introduction for buttons on remote controller For every press of “-” or “+” button, the set temperature will decrease or increase 0.5℃. Press “-” or “+” button for over 1 second, the temperature value will be changed quickly and the information will be sent until the button is loose.
Page 17
Introduction for buttons on remote controller Press this button to set left and right swing status, the circula- tion change is as follow: Left and right fixed angle button This is a general remote controller, when receiving “ ”, the swing status is the same as “...
Page 18
Introduction for buttons on remote controller Sleep 1 Cooling mode: under sleep status and after operation for 1h, the temperature of the master unit will increase 1℃, then 2℃ after 2h, after that, the unit will be operated at the set temperature.
Page 19
Replacement of batteries in remote controller people, airflow avoiding people, and circular airflow. FOLLOW: the unit will control the vertical and horizontal swing louvers automatically according to the body sensing device so as to blow air toward people. AVOID: the unit will control the vertical and horizontal swing I SENSE louvers automatically according to the body sensing device so button...
Replacement of batteries in remote controller NOTICE: Don’t mix the new battery with the old one and batteries of different types shall not be mixed. The remote controller shall be kept well; Liquid shall not flow into the remote controller; the remote controller shall avoid direct sunshine or not be put in places with high temperature.
Clean and Maintenance Read before cleaning When cleaning the air conditioner, please turn off the unit and remove the power plug, otherwise, there might be electric shock. The air conditioner shall be kept dry and please ensure that no water is used to wash the unit under any situations, otherwise, there might be electric shock.
Page 22
Clean and Maintenance Cleaning and maintenance of air guide louver 1.Dismantle air guide louver Hook Pull out the air guide louver forward with both hands. (1)Dismantle the left side, hold the connect- ing rod with the left hand and hold the left side of air guide louver with the right hand, pull it out in the direction as the fig shown (opposite direction of hook opening), to...
Malfunction analysis General phenomenon analysis...
Page 24
Malfunction analysis Phenomenon Check items Solution Power failure? Wait until power recovery. Is plug loose? Reinsert the plug. Air switch trips off or fuse is Ask professional to replace burnt out? air switch or fuse. Air condit- Wiring has malfunction? Ask professional to replace it.
Page 26
Malfunction analysis Error Code When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Error code Troubleshooting It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit.
Page 28
Safety operation of flammable refrigerant a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N e. Cutting or welding f. Carry back to the service spot for welding The refrigerant should be recycled into the specialized storage tank. Make sure that there isn’t any naked flame near the outlet of the vacuum pump and it’s well-ventilated.
Safety precautions for installing and relocating the unit 7R HQVXUH VDIHW\ SOHDVH EH PLQGIXO RI WKH IROORZLQJ SUHFDXWLRQV :DUQLQJ When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. $Q\ SUHVHQFH RI DLU RU RWKHU IRUHLJQ VXEVWDQFH LQ WKH UHIULJHUDQW FLUFXLW ZLOO FDXVH V\VWHP SUHVVXUH ULVH RU FRPSUHVVRU UXSWXUH UHVXOWLQJ LQ LQMXU\ When installing or moving this unit, do not charge the refrigerant which...
Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
Installation of indoor unit Step one: choosing installation location UP LW ZLWK WKH FOLHQW Step two: install wall-mounting frame Hang the wallPRXnting fraPe Rn the wall; aGjXVW LW in hRrizRntal pRVitiRn with the SODVWLF H[SDQVLRQ SDUWLFOHV LQ WKH KROHV 3. )L[ WKH ZDOOPRXQWLQJ IUDPH RQ WKH ZDOl ZLWK WDSSLQJ VFUHZV DQG WKHQ FKHFN LI WKH IUDPH LV ILUPO\ LQVWDOOHG E\ SXOOLQJ WKH IUDPH,I WKH SODVWLF H[SDQVLRQ SDUWLFOH LV ORRVH SOHDVH GULOO DQRWKHU IL[LQJ KROH nearby.
Page 34
Installation of indoor unit Indoor outdoor Note: Pay attention to dust prevention and take relevant safety measures when opening the hole. 5-10 Step four: outlet pipe 1. The pipe can be led out in the When select leading out the pipe direction of right, rear right, left or from left or right, please cut off the rear left.
Page 36
Installation of indoor unit 2. Make the power connection wire go hole of indoor unit and then pull it out from the front side. power connection wire with wire clip. black brown blue green Outdoor unit connection 4. Put wiring cover back and then tighten the screw. 5.
Configuration of connection pipe Standard length of connection pipe 5m、7.5m、8m Min. length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
Page 40
Configuration of connection pipe 6KHHW $GGLWLRQDO UHIULJHUDQW FKDUJLQJ DPRXQW IRU 5 'LDPHWHU RI FRQQHFWLRQ SLSH PP ,QGRRU XQLW WKURWWOH 2XWGRRU XQLW WKURWWOH &RROLQJ RQO\ FRROLQJ DQG &RROLQJ RQO\ /LTXLG SLSH *DV SLSH FRROLQJ DQG KHDWLQJ KHDWLQJ J P J P J P RU ...
Specialist’s Manual The following checks shall be applied to installations using flammable refrig- erants: – the charge size is in accordance with the room size within which the refrigerant containing parts are installed; – the ventilation machinery and outlets are operating adequately and are not obstructed;...
Page 43
Specialist’s Manual Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer's technical department for assistance.
Page 44
Specialist’s Manual Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
Page 45
Specialist’s Manual order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufac- turer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged.
Page 46
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn Web: www.gree.com 600005061890...