Step
15.Remove motor and cross flow blade
a.
Remove the screws fixing motor clamp
and then remove the motor clamp.
b.
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
c.
Remove the bearing holder sub-assy.
74
Procedure
Cross flow
Holder sub-assy
Service Manual
Motor clamp
Screws
Motor
Screw