Gree GWH09YC-K6DNA1A Service Manual page 32

Table of Contents

Advertisement

Service Manual
1. Under heating mode: auto speed under heating or auto heating mode:
a. When T
≤T
+1°C, indoor fan will operate at high speed;
amb.
preset
b. When T
+1°C<T
preset
amb.
c. When T
≥T
+3°C, indoor fan will operate at low speed;
amb.
preset
There should be at least 180s operation time during switchover of each speed.
2. Under cooling mode: auto speed under cooling or auto cooling mode:
a. When T
≥T
+2°C, indoor fan will operate at high speed;
amb.
preset
b. When T
<T
<T
preset
amb.
c. When T
≤T
, indoor fan will operate at low speed
amb.
preset
There should be at least 210s operation time during switchover of each speed.
(7) Buzzer Control
The buzzer will send a "Di" sound when the air conditioner is powered up or received the information sent by the remote control or there is
a button input, the single tube cooler doesn't receive the remote control ON signal under the mode of heating mode.
(8) Auto button
If the controller is on, it will stop by pressing the button, and if the controller is off, it will be automatic running state by pressing the button,
swing on and light on, and the main unit will run based on the remote control if there is remote control order.
(9) Up-and-Down Swinging Control
When power on, the up-and-down motor will firstly move the air
deflector to o counter-clockwise, close the air outlet.
After starting the machine, if you don't set the swinging functi on,
heating mode and auto-heating mode, the up-and-down air deflector
will move to D clockwise; under other modes, the up-and-down air
deflector will move to L1. If you set the swinging function when you start
the machine, then the wind blade will swing between L and D. The air
deflector has 7 swinging states: Location L, Location A, Location B, Location C,
Location D, Location L to Location D, stop at any location between L-D (the included angle between L~D is the same).
The air deflector will be closed at 0 Location, and the swinging is effectual only on condition that setting the swinging order and the inner
fan is running. The indoor fan and compressor may get the power when air deflector is on the default location.
(10) Display
① Operation pattern and mode pattern display
All the display patterns will display for a time when the power on, the operation indication pattern will display in red under standby status.
When the machine is start by remote control, the indication pattern will light and display the current operation mode (the mode light in-
cludes: Cooling, heating and dehumidify). If you close the light key, all the display patterns will close.
② Double-8 display
According to the different setting of remote control, the nixie light may display the current temperature (the temperature scope is from 16°C
to 30°C) and indoor ambient temperature. The set temperature displayed in auto cooling and fan mode is 25°C and the set temperature
displayed in auto heating mode is 20°C. Under heating mode, nixie tube displays H1 or heating indicator is off 0.5s and blinks 10s in de-
frosting.(If you set the fahrenheit temperature display, the nixie light will display according to fahrenheit temperature)(11) Protection function
and failure display
E2: Freeze-proofing protection
F1: Indoor ambient sensor start and short circuit (continuously measured failure in 5s)
F2: Indoor evaporator sensor start and short circuit (continuously measured failure in 5s)
F3: Outdoor ambient sensor start and short circuit (continuously measured failure in 30s)
F4: Outdoor condenser sensor start and short circuit (continuously measured failure in 30s, and don't measure within 10 minutes after
defrosted)
F5: Outdoor exhausting sensor start and short circuit (continuously measured failure in 30s after the compressor operated 3 minutes)
H3: Overload protection of compressor
P1: Nominal cooling and heating test
P3: Medium cooling and heating test
(12) Drying Function
You may start or stop the drying function under the modes of cooling and dehumidify at the starting status (The modes of automatism,
heating and air supply do not have drying function). When you start the drying function, after stop the machine by pressing the switch
button, you should keep running the inner fans for 2 minutes under low air damper (The swing will operate as the D1 status within 2
minutes, and other load is stopped), then stop the entire machine; When you stop the drying function, press the switch button will stop the
machine directly.When you start the drying function, operating the drying button will stop the inner fans and close the guide louver.
(13) Memory Function
When interrupting the power supply memory content: mode, swing function, light, set temperature and wind speed.
After interrupted the power supply, the machine will start when recovering the power according to the memory content automatically.
Installation and Maintenance
<T
+3°C, indoor fan will operate at medium speed;
preset
+2°C, indoor fan will operate at medium speed;
preset
H
e
i t a
g n
a
g n
e l
O(0°)
E4: Exhausting protecti on
H5: Module protection
P2: Maximum cooling and heating test
P0: Minimum cooling and heating test
C
o
i l o
g n
a
g n
e l
O(0°)
L
A
B
C
D
E5: Overcurrent protection
PH: High-voltage protection
H
e
i t a
g n
a
g n
e l
O(0°)
L1
A1
B1
C1
D1
E6: Communication failure
PL: Low-voltage protection
C
o
i l o
L
A
B
C
D
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh12yc-k6dna2aGwh09yc-k6dna2aGwh12yc-k6dna1a

Table of Contents