Error - Settings - Interroll MultiControl Instruction Manual

Hide thumbs Also See for MultiControl:
Table of Contents

Advertisement

Initial start up and operation

Error - Settings

Network Error
Monitoring the communication between MultiControl and PLC:
Ignore:
Warning:
Immediate Stop:
If the MultiControl is operated without PLC, we recommend the setting "Ignore".
If the MultiControl is operated with PLC, we recommend the setting "Immediate
Stop".
Over Voltage Error
Too high supply voltage:
Ignore:
Warning:
Immediate Stop:
36
Error is not displayed.
Error is indicated by the fault LED flashing twice.
The conveying process is not interrupted.
Error is indicated by the fault LED flashing twice.
The conveying process is interrupted.
Error is not displayed.
Error is indicated by fault LED flashing six times.
The conveying process is not interrupted.
Error is indicated by fault LED flashing six times.
The conveying process is interrupted.