Zone Run Times - Weathermatic PROLINE PL800 Owner's Manual

Hide thumbs Also See for PROLINE PL800:
Table of Contents

Advertisement

www.weathermatic.com
Start times are selectable
in 10-minute increments.
Note: Be sure you
select the AM/PM
time as desired by
scrolling past 12. (For
international users,
the display will show
international hours
instead of AM/PM.)
If a run time overlaps the
next program start time,
the ProLine™ controller
will stack the start times
within each program
and between programs, beginning those operations at the
time the previous operation is completed, beginning with
start time 1 in Program A. If a concurrent program in D
is running at the same time as a program in A, B or C,
the display will alternately
show the icon for both
programs in the display.
Note: Run/Soak
feature can
reduce the need
to set multiple
start times for the purpose
of preventing runoff. Using
the combination of multiple
start times and Run/Soak
cycles can lead to extended
watering windows since
Run/Soak cycles are applied
to each start time. See Run/
Soak, Section 5.4.
Note: If dis-
play shows "0
ZONES," this
indicates no
SLM4 modules are cur-
rently installed or have
ever been installed under
AC power with the control
panel firmly closed.

3.3 Zone Run Times

Your ProLine™ controller will
display remaining hours,
minutes and seconds when
a zone is watering. However,
in this position you are only
required to set minutes (or
hours and minutes) for each zone as desired for operation
time. Seconds are not selectable.
Use NEXT and BACK buttons to select zone for run time
setting. All zones are selectable from 1 minute to 9 hours
and 55 minutes. Run times of OFF to 59 minutes are
selectable in one minute increments. Run times of 1 hour to
9 hours 55 minutes are selectable in 5-minute increments.
Use  or  arrow buttons to set flashing time values for
each zone. If a zone is not to be used, set it to OFF.
Push PGM button to assign zone time in one or more
programs. Note: Program D is for concurrent operation
for micro irrigation zones. Zones assigned to Program D
cannot be assigned to Program A, B, or C. Display will say
USED if attempt is made to enter time in A, B, or C for a
zone already assigned run time in D.
Caution: If an unused zone is turned on and activates a
pump start relay, the pump may overheat or cause a pipe
to burst. To prevent operating a pump with no flow (dead
heading), make sure all unused zones are set to OFF.
6
Programming 3.0