4.0 Manual Start Functions
4.0 Manual Start Functions
The ProLine™ controller has three dial positions for manual
system starts:
4.1 Manual Zone
Manual Zone allows user
to water a single zone for
specified period of time. Use
NEXT and BACK buttons to
select zone. Use and
arrows to select run time for
the zone. A zone can be operated with the Manual Zone
function regardless of whether the zone has an assigned
run time. You must return dial to RUN for Manual
Zone operation to begin. All manual watering operations
will override watering day settings, omit settings, and rain/
freeze events.
4.2 Manual Test
The Manual Test can be
used to set a test run time
for all zones which have
an assigned zone run time
in any program. Any zone
without an assigned zone
run time will NOT run in the Manual Test. Use and
arrow buttons to set Manual Test run time. The Manual Test
www.weathermatic.com
can be set to run a minimum of 10 seconds or a maximum
of 10 minutes. You must return dial to RUN for Manual
Test operation to begin.
Manual Test will detect open circuits (less than 30 mA
draw) on any used zone or a short on any output (master
valve or zone). If the display indicates FAULT while running
a Manual Test, refer to Advanced Functions to identify the
FAULT.
4.3 Manual Program
Manual Program allows you
to start any program set up
in the controller; A, B, C or
D. Zones will run for the
time set at Zone Run Times
for the selected program.
•
Turn dial to Manual
Program. OFF will appear in the screen.
•
Use and arrows to select the program you want
to run (PROG A, B, C or D)
•
Return dial to RUN. Program will commence
watering. At the end of the manual watering cycle,
the controller will return to automatic RUN mode.