Program Start Times; Zone Run Times - Weathermatic ProLine 800 Series Owner's Manual

Table of Contents

Advertisement

2.2 Program Start Times

Set Start Time for each program to be
used (A, B, C and D). If more than one
program start time is desired, refer to
NUM STRT, in Advanced Menu. The
program will start at the time you
designate and will water all zones with
set Zone Run Times for that program.
For most watering programs set only Start Time #1.
The #1 Time will water all zones with Zone Run Times
set in that program in consecutive order. Extra start
times will re-run all zones. Extra start times may be
used for new planting grow-in or other special local
conditions. Unused start times must be set in the
OFF position. To set a start time at OFF, press on
either arrow button until you reach the OFF postion
located at midnight.
When setting program start times, check the program icon in the
display to see whether you are working in A, B, C or D. Use PGM
button to move between programs. Use NEXT and BACK buttons
to move between start times. Use up and down arrow buttons to
set each start time desired. Start times are selectable in 10-minute
increments.
Note:
Be sure you select the AM/PM time as desired by scrolling
past 12. (For international users, the display will show the 24-hour
time format instead of AM/PM.)
RUN
RUN
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
M A N UA L P R O G R A M
M A N UA L P R O G R A M
P R O G R A M STA R T T I M E S
M U LT I M E T E R
M U LT I M E T E R
ZO N E R U N T I M E S
ZO N E R U N T I M E S
VA LV E LO C ATO R
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
SENSOR OPERATION
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
MENU
MENU

2.3 Zone Run Times

Your ProLine® controller will display
remaining hours, minutes and seconds
when a zone is watering. However, in
this position you are only required to
set minutes (or hours and minutes)
for each zone as desired for operation
time. Seconds are not selectable.
Use NEXT and BACK buttons to select
zone for run time setting. All zones are selectable from 1 minute
to 9 hours and 55 minutes. Run times of OFF to 59 minutes are
selectable in one minute increments. Run times of 1 hour to 9
hours 55 minutes are selectable in 5-minute increments. Use UP or
DOWN arrow buttons to set flashing time values for each zone. If a
zone is not to be used, set it to OFF.
Push PGM button to assign zone time in one or more programs.
Caution: If an unused zone is turned on and activates a pump start
relay, the pump may overheat or cause a pipe to burst. To prevent
operating a pump with no flow (dead heading), make sure all
unused zones are set to OFF.
Note:
Run/Soak feature can reduce the need to
set multiple start times for the purpose of
preventing runoff. Using the combination of
multiple start times and Run/Soak cycles can
lead to extended watering windows since Run/Soak cycles
are applied to each start time. See Run/Soak, Section 5.4.
Note:
If display shows "0 ZONES," this indicates
no SLM4 modules are currently installed or have
ever been installed under AC power with the
control panel firmly closed.
2.0 Programming
RUN
RUN
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
M A N UA L P R O G R A M
M A N UA L P R O G R A M
P R O G R A M STA R T T I ME S
P R O G R A M STA R T T I M E S
M U LT I M E T E R
M U LT I M E T E R
ZO N E R U N T I M E S
VA LV E LO C ATO R
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
SENSOR OPERATION
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
MENU
MENU
http://support.weathermatic.com
4

Advertisement

Table of Contents
loading

Table of Contents