Error Log Clear (2103) - Omron CJ1W-CORT21 Operation Manual

Cj-series. user defined can unit nj-series cpu unit
Hide thumbs Also See for CJ1W-CORT21:
Table of Contents

Advertisement

Response Block
Issuing an Error Log Read command will result in the following response End Codes.
21
02
Command
code
End Code (hex)
0000
1001
1002
1103
110C

4-2-10 Error Log Clear (2103)

The Error Log Clear command clears the number of records stored in the User Defined CAN Unit Error
Log.
Command Block
CJ-series User Defined CAN Unit Operation Manual for NJ-series CPU Unit (W517)
Maximum
Number
End Code
Number
of stored
of stored
records
records
Description
Normal Completion
Command length exceeds
maximum command length
The command length is
insufficient for the smallest
command
Beginning Record Number
is Out of Range
The Number of Read
Records is 0
21
Command
code
4 Message Communications
10 bytes each
Number
Error log records
of records
Condition
---
---
---
Requested beginning record
number is invalid
There is an error in one of the
parameter settings
03
Correction
Too many parameters sent in
the command.
Correct the command and re-
send.
Too few parameters sent in
the command.
Correct the command and re-
send.
Correct the beginning record
number and resend.
Check the command data and
correct the parameters.
4-23