1 Features and System Configuration
1-3
Specifications
1-3-1
User Defined CAN Unit
General Specifications
General specifications of the CJ-series User Defined CAN Unit conform to those of the NJ-series
CPU Units.
Functional and Performance Specifications
Item
User Defined CAN Unit model
Applicable Controller
Unit classification
Applicable unit numbers
Mounting position
No. of Units that can be mounted
Words allo-
I/O port (without power OFF retention)
cated in the
(Access via the device variables for CJ-
memory
series Unit)
used for
I/O port (with power OFF retention)
CJ-series
(Access via the device variables for CJ-
Unit
series Unit)
Supported connections (communications)
Message
Message communications for configura-
communi-
tion
1
cations*
Message communications
Other functions
Setting section
Display section
Front connector
Communications power supply voltage
Current consumption
External dimensions
Weight
Standard accessories
1-20
CJ1W-CORT21
NJ Series
CPU Bus Unit
0 to F
CPU Rack or Expansion Rack
16 Units max.
25 words/Unit
CPU Unit to User Definied CAN Unit: 10 words for the software switches and sta-
tus words. The remaining 15 words are reserved for future use.
100 words/Unit
Reserved for future use
Message buffers and message communications (FINS*
All conform to CAN communications standards.
• Configuration of Input and Output buffers with a maximum of 640 for each type
• Configuration of send and receive flags area (limit of one of each type)
• Configuration of baud rate and sample point
Message communications to send/receive a CAN message directly
Error history can be accessed using a message command.
Rotary switches for Unit No. (hexadecimal x 1)
Front panel DIP switch for Baud rate
Two indicators(2 colors): One green to indicate the Unit is powered. One red to
indicate and error status.
Two 7-segment displays: Displays CAN communication status and error code.
Two dot indicators within the 7-segment display: Left dot indicates communica-
tion status configuration set from message communications. Right dot indicates
communication is configured and enabled.
One communications connector (communications data: CAN H and CAN L, net-
work power supply: CAN_V+, ground CAN_GND and shielded)
Use the XW4B-05C1-H1-D connector provided to connect the communications
cable.
• Use the XW4B-05C4-T-D connector sold separately for multi-drop connec-
tions.
11 to 25 VDC (supplied from the communications connector)
Communications power supply: 18 mA at 24 VDC, (supplied from the communi-
cations connector)
Internal circuit power supply: 290 mA max. at 5 VDC (supplied from the Power
Supply Unit)
31 x 90 x 65 mm (W x H x D)
118 g (including the connector provided)
One XW4B-05C1-H1-D connector to connect to a node from a T-branch Tap.
CJ-series User Defined CAN Unit Operation Manual for NJ-series CPU Unit (W517)
Specification
1
).