Kontron CP6011 Quick Reference

Kontron CP6011 Quick Reference

6u cpci single processor, cpci pentium-m dual pmc

Advertisement

Quick Links

CP6011
CP6011
CP6011
... always a Jump ahead!
6U cPCI Single Processor
CPCI Pentium-M Dual PMC
QUICK REFERENCE
Board Rev.
1
Document version 1.3

CONNECTORS

CONNECTORS
CONNECTORS
J1-J5
CompactPCI
J14
IDE Mezzanine
Post Code
64-bit PCIX Mezzanine & PIM
J6
JN1A-JN4A
Memory SODIMM 1-2
64-bit PCIX Mezzanine
J7-J8
JN1B-JN3B
J9

Ethernet Management

SW1
Reset Button (faceplate)
COM1 (faceplate) (RJ-45)
Battery
J10
BT1
USB (faceplate)

LEDs

J11
LP1
J12
Compact Flash
J16
JTAG
Hot Swap Switch
J13
JUMPER SETTINGS (
Default Setting)
JUMPER SETTINGS (
Default Setting)
W1 (1-2), W1 (3-4)
W6, W7, W8

PMC A VIO Settings

Backplane PCI Maximum Speed
W1(1-2)
W1(3-4)
3.3V VIO
out
in
PCI 33MHz
5V VIO
in
out
PCI 66MHz
PCIX 66MHz
W1 (5-6) User Jumper
PCIX 100MHz
PCIX 133MHz
Low
in
Bridge Disabled
High
out
Brisge Dis. In I/O Slot
W2(1-2) Console Redirection
W9 Onboard IPMI
in
Enabled
Disable
out
Disabled
Enable
W2(3-4) Reserved
W10 CompactFlash
out
Master
W2 (5-6) Onboard Video
Slave
Disabled
in
W11, W12
Enabled
out

PMC B VIO Settings

W3 Reserved
3.3V VIO
out
5V VIO
W4, W5 COM2 Terminations
W13 Clear CMOS
RS-422/485 modes only
W4
W5
Clear CMOS
With termination
in
in
Normal
Without termination
out
out

First Level Debugging

Blue LED always ON
Blue LED OFF
1. Check the jumper settings
1. Remove all peripheral and external connections.
2. Verify if the board is in the correct CPCI slot.
2. Check the memory
3. Verify PMC VIO jumpers
3. Check post code on
4. Verify the power supply.
Blue/User led.
Warning:
Both red LEDs always ON
Be sure you have the right
1. Check PMC VIO jumpers
backplane VIO setting
according to the board
configuration.
AMBER: Activity
Lights ON
while transferring
Green : Link
Lights ON when
the link is established
Note : LED colors
may change
8
W6
W7
W8
in
in
in
1
out
in
in
BLUE / USER LED
in
out
in
out
out
in

USER LED

out
out
out
in
out
out
8
in
in
out
1
in
out
1
in
out
W11
W12
in
out
out
in
in
out
PMC A
J9
ETHERNET MANAGEMENT
LP1

RESET BUTTON

SW1
COM1
J10
USB
J11
4
PMC B
CP6011
WARNING
Make sure that only W1(1-2) or
W1(3-4) is set. Only one at the time
must be installed.
J6
1
4
B

J7

J8

A
JN4A is routed to J4 for the
PIM adapter, using 32
differential pairs
Lithium
3.6V
MCH
E7501
BT1
Rage
Mobility M
ICH3-S
J12
PCI6540
P64H2
1
2
4
6 8 10
2
4
6 8 10
12
14
2
2
2
2
2
2
2
2
2
2
J13
1
3
5
7 9
11
13
1
1
1
1
1
1
1
1
1
1
1
3
5
7 9
J16
W3
2
2
2 2 2 2 2
2 2 2
WARNING
Make sure that only W11 or W12 is
1
1
1
1 1 1 1
1 1 1
set. Only one at the time must be
installed.
E D C B A
22
J5
1
1
25
15
J4
11
2
4
6
2
4
6
W2
1
3
5
W1
1
3
5
1
1
19
E D C B A
J3
Pentium
M
1
1
22
J2
1
1
25
J1
15
11
63
64
1
1
1
J14
E D C B A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP6011 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kontron CP6011

  • Page 1 WARNING CP6011 CP6011 CP6011 Make sure that only W1(1-2) or W1(3-4) is set. Only one at the time ... always a Jump ahead! 6U cPCI Single Processor must be installed. CPCI Pentium-M Dual PMC QUICK REFERENCE Board Rev. AMBER: Activity Document version 1.3...
  • Page 2 POST:DATA The Technical Reference Manual and the Quick Reference DATA+ POST:CLOCK PIM:54 / D0+ PIM:56 / D0- can be downloaded from Kontron Web site at: PIM:53 / DP1+ PIM:55 / DP1- PIM:49 / D1+ PIM:51 / D1- PIM:50 / D2+ PIM:52 / D2- http://www.kontron.com...

Table of Contents