7. TCR SETUP
TCR PCB
Reset Button
DIL Switch
DIL SWITCH
DIL switches 1 to 5 are used to set the TCR ID.
DIL switches 6, 7 & 8 are not used.
TCR ID's must start at 0 and run sequentially to 31 max – do not duplicate ID's.
ID's are set in Binary as below;
DIL Switch No.
Binary Code
ID 0
ID 1
ID 2
ID 3
ID 4
ID 31
All TCR's must be assigned in the Display Panel(s) as House Code 000 with ID's starting at
065 for TCR 1 and running sequentially to 096 for TCR 32. See "ADD ATX" in the System
Configuration section of the Display Panel Installation Guide Doc No. FM5500.
LED's
Status LED1 on the PCB will flash green when a Telecare radio transmission received.
LED's 2 & 3 on the PCB indicate the TCR is connected to the RS485 Bus. LED2 (yellow) should be
permanently illuminated; LED3 (red) will flash when data is sent to the Master Panel.
RESET BUTTON
Always press the RESET button after DIL switch settings have been changed.
PROGRAMMING
Telecare devices must be allocated to a Call Point from the Telecare option on the Master Panel setup.
See the Touchsafe Pro Display Panel Installation Guide (Aidcall Doc No. FM5500) for details.
Note: an Engineers Logon is required.
1
2
3
1
2
4
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
Status LED
RS485 TX/RX LED's
Power & RS485
Screw Terminals
4
5
6
8
16
N/A
N/A
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
7
8
N/A
OFF
OFF
OFF
OFF
OFF
OFF
Doc No. FM5565 issue B Page 10