7. TCR SETUP  
 
TCR PCB 
 
 
 
 
 
 
 
 
Reset Button 
 
 
DIL Switch 
 
 
 
 
 
 
DIL SWITCH 
 
DIL switches 1 to 5 are used to set the TCR ID. 
DIL switches 6, 7 & 8 are not used. 
TCR ID's must start at 0 and run sequentially to 31 max – do not duplicate ID's.  
ID's are set in Binary as below; 
 
DIL Switch No. 
Binary Code 
ID 0 
ID 1 
ID 2 
ID 3 
ID 4 
 
ID 31 
 
 
 
All TCR's must be assigned in the Display Panel(s) as House Code 000 with ID's starting at 
065 for TCR 1 and running sequentially to 096 for TCR 32. See "ADD ATX" in the System 
Configuration section of the Display Panel Installation Guide Doc No. FM5500.
 
 
 
LED's 
 
Status LED1 on the PCB will flash green when a Telecare radio transmission received. 
LED's 2 & 3 on the PCB indicate the TCR is connected to the RS485 Bus. LED2 (yellow) should be 
permanently illuminated; LED3 (red) will flash when data is sent to the Master Panel. 
 
RESET BUTTON 
 
Always press the RESET button after DIL switch settings have been changed. 
 
PROGRAMMING 
 
Telecare devices must be allocated to a Call Point from the Telecare option on the Master Panel setup.  
See the Touchsafe Pro Display Panel Installation Guide (Aidcall Doc No. FM5500) for details.  
Note: an Engineers Logon is required. 
  
 
2
3
2
4
OFF 
OFF
OFF
OFF
ON 
OFF
OFF
OFF
OFF 
ON
OFF
OFF
ON 
ON
OFF
OFF
OFF 
OFF
ON
OFF
 
 
ON
ON
ON
ON
Status LED 
RS485 TX/RX LED's 
Power & RS485 
Screw Terminals 
4
5
6
8
16
N/A
N/A 
OFF
OFF
OFF 
OFF
OFF
OFF 
OFF
OFF
OFF 
OFF
OFF
OFF 
OFF
OFF
OFF 
ON
OFF
OFF 
7
N/A 
OFF 
OFF 
OFF 
OFF 
OFF 
 
OFF 
 
Doc No. FM5565 issue B Page 10   