Projecta SC300D Instruction Manual page 10

Solar charge remote
Hide thumbs Also See for SC300D:
Table of Contents

Advertisement

Battery voltage parameters
(Parameters is in 12V system at 25
Control voltage parameters
Battery charging setting
Over voltage disconnect voltage
Charging limit voltage
Over voltage reconnect voltage
Equalize charging voltage
Boost charging voltage
Float charging voltage
Boost reconnect charging voltage
Low voltage reconnect voltage
Under voltage warning
reconnect voltage
Under voltage
warning voltage
Low voltage disconnect voltage
Discharging limit voltage
Equalize duration
Boost duration
Note: Battery voltage setting please in strict accordance with:
1. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage
≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging
Voltage;
2. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage;
3. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit
Voltage;
4. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage;
5. Boost Reconnect Charging Voltage > Low Voltage Disconnect Voltage.
10
o
C , please use X 2 in 24V.)
Gel
Sealed
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
14.6V
14.2V
14.4V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
2 hrs.
2 hrs.
2 hrs.
Flooded
User
16.0V
9–17V
15.0V
9–17V
15.0V
9–17V
14.8V
9–17V
14.6V
9–17V
13.8V
9–17V
13.2V
9–17V
12.6V
9–17V
12.2V
9–17V
12.0V
9–17V
11.1V
9–17V
10.6V
9–17V
2 hrs.
0–3 hrs.
2 hrs.
0–3 hrs.

Advertisement