PREVENTATIVE MAINTENANCE

Quarterly:
• Check Coolant Level in Reservoir. Add approved Perlick Coolant Solution (63299-1) as needed to maintain
the coolant level in the reservoir.
• Check Coolant Concentration Ratio. Using an approved device, ensure that the concentration level has not
declined below a 30% concentration. Approved devices include but are not limited to refractometers.
• Clean Condenser as required. This should be performed more often if unit is installed in an excessively dirty
or dusty environment. Remove louvered grille to expose condenser. Remove dirt from the fin surface using
a brush, vacuum or compressed gas.
Replacement Parts (RD060, RD120)
COMPONENT
Condensing Unit, 3/4 HP, 115V
Drier, R134A, 3/8" ID inlet, X
Valve, Expansion, Constant
Heat Exchanger, Brazed Plate
Coupling, 3/4" (FIPT X FIPT)
Fitting, 1/2" Hose X 3/4" NPT
Relay, Enclosed, DPDT, 8 pins
Junction Block
Wire Harness, Cond. unit
Wire, Jumper, 14-1 AWG, Black
Wire, Jumper, 14-1 AWG, Black
Wire, Jumper, 14-1 AWG, White
Wire, Jumper, 14-1 AWG, White
Grille, End, SS Power Pak
Switch, Single Pole, Rocker
Replacement Parts (Outdoor)
COMPONENT
Fan Control
Crankcase Heater
Crankcase Heater Control
Power Cord, 15A
COMPONENT
Cord, 8FT-15 AMP, 3WIRE Plug-in
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
ARCTICPOUR
Operation/Installation Manual
RD060
C22670
63297
63826
63300A
63360
63361
67511
57946
61834-2
63322
63320
63319
63318
64197-1SS
63303
RD060-O
67623
67625
67624
RD060
C22297
11
RD120
C22668
63297
63826
63300A
63360
63361
67511
57946
61852
63322
63320
63319
63318
64285-1SS
63303
RD120-O
67623
67624
RD120
Form No. Z2339