Connecting To A Trunk Housing - Perlick ARCTICPOUR RD060 Installation And Operation Instructions Manual

Table of Contents

Advertisement

CONNECTING
REFRIGERATION
GLYCOL BATH (cont.)
• Make coolant line connections and clamp using
included Oetikers (Inlet fitting is located on the
outside of the cabinet, outlet fitting is located inside
the cabinet). Insulate the glycol lines completely to
avoid condensation and unnecessary heat gain.
(Ensure that the feed line is connected to the inlet
fitting and the return line to the outlet fitting).
• Connect Low Voltage wires to the two wires with
bell connectors on them [(1) Black wire, (1) White
wire]. See Wiring Diagrams (pages 11-13) for
proper connections.
• Connect Refrigeration Deck to proper power source.
Permanently connected units should be wired per
the wiring diagram and circuit should be sized
according to the I.D. plate's electrical specifications.
The circuit should be sized in accordance with the
electrical requirements of the unit as well as in
compliance with all National and Local codes (codes
may require a separate disconnect for these units).
NOTE: Electrical circuit should be a dedicated
circuit for use only with the Refrigeration Deck.
• Make Coolant Line connections on Glycol Bath, one
to pump outlet, the other to bath return tube and
clamp using included Oetikers (Coolant Connector
feed line).
• Remove the top front panel on the bath and the
electrical box front cover.
• Connect low voltage wires to the low voltage
transformer secondary wires with bell connectors
(Blue and Yellow wires).
• Ensure power switches for the pump motor(s) are
in the OFF position. (Check transformer to ensure
the leads are connected to the low voltage side of
the transformer). Make the electrical connections
per the wiring diagram. The circuit should be sized
in accordance with the electrical requirements
e unit as well as in compliance with all
of th
National and Local Codes (codes may require
a separate disco
Electrical circuit should be a dedicated circuit
for use only with the Glycol Bath.
• Re-install Electrical Box Cover.
CONNECTING TO FLASH CHILL COILS
If the Glycol Bath includes flash chill coils, then
follow these instructions for proper connections:
Locate Glycol Bath in-line with convenient
point along the trunk housings to splice into
the product lines and glycol feed line within the
trunk housing (this location could be inside the
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
DECK
nnect for these units). NOTE:
ARCTICPOUR
Operation/Installation Manual
AND
walk-in cooler, immediately outside the walk-
in cooler or anyplace along the trunk housing
up to the point of connection to the dispensing
head).
To make the proper connections, Flash Chill
Connector kit 68455 is required.
instructions included with kit 68455 make the
necessary connections for each product tube
and coolant line.
GLYCOL BATH INSIDE WALK-IN COOLER
• Connect and clamp incoming product lines to inlet
of flash chill tube(s). Connect and clamp outgoing
product lines to outlet of flash chill tube(s). Using
included coolant loop coils from kit 68455, (pick
the correct size based on the number of flash chill
tubes) hook up to glycol lines (see kit instructions
68455-INS).
• Tape and insulate the coolant loop and outgoing
product tubes to prevent condensation on heat
gain into the newly flash chilled product lines. The
product lines should be taped to the coolant lines
and then combined should be fully insulated to the
trunk housing insulation.
GLYCOL BATH LOCATED ALONG THE TRUNK
HOUSING.
In this scenario, the pump to maintain the product tem-
perature within the trunk housing is going to go from
the pump outlet to the flash chill coolant loop, then
from the flash chill coolant loop to the trunk housing
coolant line to the dispensing head, then back through
the trunk housing to the walk-in cooler and finally back
to the Glycol Bath.
• If the trunk housing is located along the path of
the trunk housing, then the trunk housing must
be spliced, similarly to dropping product lines at a
dispensing head, except in this case all the product
lines are being dropped to the flash chill coils along
with the feed line of the glycol circuit.
• Once all coolant and product connections are made
using the included oetiker clamps, product lines
are securely taped to the coolant lines and then all
product lines and coolant lines are insulated using
the included insulation to prevent condensation and
heat leak.

CONNECTING TO A TRUNK HOUSING

• Inspect pump outlet port for cleanliness
• Cut supplied coolant tubing (#54588) to required
length to reach from Glycol Bath to Trunk Housing
connection point.
7
Using
Form No. Z2339
Rev. 04.17.2018