WARNING:
Shut off the electricity to the unit before cleaning
the condenser and other routine maintenance.
Cleaning:
To clean stainless steel exterior or interior surfaces,
use a soft, non-abrasive stainless steel cleaner to
wipe down the surfaces.
Glass doors can be cleaned using any standard
glass cleaner available on the market.
To clean interior non-metallic surfaces and remov-
able parts, wash with a mild solution of soap and
lukewarm water with a little baking soda. Rinse
and dry thoroughly. Avoid getting water on lights,
control panel, fan motor and unfinished wood wine
rack faces.
CAUTION:
do not use abrasive cleaners or cloths on
any of the interior or exterior surfaces or
removable parts.
Cleaning the Condenser:
The condenser should be cleaned every 3 months.
The condenser is located behind the toe plate.
Remove the toe plate and use a soft bristle brush
and vacuum to remove dust and lint. Avoid damag-
ing or crushing the condenser fins or tubing. Upon
completion, re-install the toe plate.
CAUTION:
Failure to clean the condenser could result in
temperature loss or mechanical failure. Clean
this area every three months.
Avoiding Stainless Steel Corrosion:
Corrosion can be prevented by following product
cautions, cleaning instructions and avoiding use of
certain chemicals or objects which will cause stain-
less steel corrosion.
Stainless Steel Enemy:
n Steelwool or steel scouring pads
n Cherry, Orange or Olive Juice
n Chlorine bleach
n Sharp objects
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
SINGLE dOOR FROSTER ONLY
defrost System - Hot Gas defrost
This system consists of six-hour, as well as a four-
hour defrost cycle which includes a 20 minute
evaporator defrost. The six-hour defrost cycle is
manually activated and automatically terminated,
while the four-hour cycle is completely automatic.
The Six-Hour Solid-State defrost Timer:
This timer shuts off the power to the condensing
unit, the evaporator fan and automatic four-hour
defrost timer. To activate the six-hour defrost sys-
tem, depress the defrost switch located in the front
grille of the cabinet. An amber light will illuminate
and the defrost cycle will begin.
When the defrost cycle ends, the light goes off and
the cabinet resumes normal operation. To manually
cancel the defrost cycle, momentarily unplug the
unit.
The Four-Hour defrost Timer:
This timer ensures that frost will not buildup on
the evaporator coil. Every four hours the hot gas
by-pass valve is opened and hot gas is circulated
through the evaporator coil. The defrost cycle
is terminated when the coil is clear of frost. The
defrost cycle lasts for approximately 20 minutes.
During normal operation it is recommended that
the doors are not left open to prevent excessive
frost buildup on the coil..
7
Form No. Z2288
Rev. 05.21.10

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HC24RS and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Hc24wsHc24fs

Table of Contents