Page 2
Revisions—Changes in this publication since the last revision are indicated by a black line alongside the text. Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless otherwise expressly undertaken.
Page 3
Start-up On- and off-highway Mobile Applications: Unless Woodward's control functions as the supervisory control, customer should install a system totally independent of the prime mover control system that...
Page 4
Do not touch the components or conductors on a printed circuit board with your hands or with conductive devices. To prevent damage to electronic components caused by improper handling, read and observe the precautions in Woodward manual 82715 , Guide for Handling and Protection of Electronic Controls, Printed Circuit Boards, and Modules.
Page 5
Be careful not to push the drive shaft into the governor. Improper alignment or too tight a fit between any of the parts can result in part wear or seizure. This can also cause jiggle in the governor output. Woodward...
Page 6
Refer to Figures 2A and 2B, Outline of PG-EG Governor! Actuator, and make all required hydraulic connections. Refer to the wiring diagram provided with the unit for conformation of the mating electrical connections. The plant wiring diagram included with the electronic control will provide other details about electrical connections. Woodward...
Page 7
Manual 54065 PGA-EG, PGG-EG, PGM-EG Installation Figure 2A. Outline Drawing of the PG-EG Governor/Actuator Woodward...
Page 8
PGA-EG, PGG-EG, PGM-EG Installation Manual 54065 Figure 2B. Outline Drawing of the PG-EG Governor/Actuator Woodward...
Page 9
If the oil level is high, oil should be drained. If the dipstick shows low level, add new, clean oil. Refer to Woodward manual 25071, Oils for Hydraulic Controls, for more information on selection of oils for use in hydraulic actuators (governors). Proper selection of the oil used in the actuator is necessary for the best governor performance and maximum service life.
Page 10
Be prepared to make an emergency shutdown when starting the engine, turbine, or other type of prime mover, to protect against runaway or overspeed with possible personal injury, loss of life, or property damage. Woodward...
Page 11
Once the needle valve adjustment is correct, it is not necessary to change the setting unless there is a change in oil viscosity. Additional adjustment may be necessary if stability problems exist at full speed-full load conditions Woodward...
Page 12
200 psi (1379 kPa) PG-EG 300 360 psi (2482 kPa) PG-EG 500 280 psi (1931 kPa) To check the internal pressure attach a pressure gauge in the .562-18 straight- thread port indicated as oil from booster outlet Number 1 in Figure 2B. Woodward...
Page 14
Email and Website—www.woodward.com Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address / phone / fax / email information for all locations is available on our website.
Need help?
Do you have a question about the PGA-EG 200 and is the answer not in the manual?