6.5.18.1 Relay start time (ST)
Set the relay start time.
Note
This option is available only if RE is set to tb.
Note
The relay start time can be set from 0 minute to the total of time of all the cycles minus 1
minute.
AX Press
or
AY Press
to validate the selection and move to the next parameter.
6.5.18.2 Relay end time (ET)
Set the relay end time.
Note
This option is available only if RE is set to tb.
Note
The relay end time can be set from start time to the total of time of all the cycles.
AZ Press
or
BA Press
to validate the selection and move to the next parameter.
6.5.19. Flow based relay setting (VR)
Select the relay setting.
Note
The relay can bet set upon a time base (tb) or a flow base (Fb). Only one method can be used
at a time.
Note
This option is available only if RE is set to OFF.
Note
If set to Fb, the controller will enable and disabled the relay output every time the set volume
interval is reached for the set time ON.
BB Press
or
BC Press
to validate the selection and move to the next parameter.
Ref. MKT-IM-004 / A - 18.04.2017
to set the relay start time.
to set the relay end time.
to select between Fb and OFF.
Installer Manual Fleck 5800 - SXT - Programming
59 / 92