NH-1800
C0045
C0046
C0047
C0048
C0049
C004A
C004B
C004C
C004D
More note than requested were
dispensed.
No. of requested notes < No. of notes
passing CS13(NS4)
Occurs while notes are being dispensed.
Cash Dispenser Unit Hardware Failure
1 st Cassette Miss-feed
Incorrect bill count
Request to dispense 0 note.
Command error in the Control Electronics
control part
Note jam
CS1∼CS4(NS2~NS3) : Note Passting
Time >= 400ms
CS4~CS13(NS3~NS4) : Note Passting
Time >= 500ms
Occurs while notes are being dispensed.
Three or more consecutive rejection.
Occurs while notes are being dispensed.
The number of dispensed notes does not
match.
No. of notes passing CS13(NS4) <> No. of
notes passing CS1(NS2).
Occurs after notes are dispensed.
The cassette has not been installed before
3. Check if the note type on the index
set by the Control Electronics matches
with the actual note type.
1. Check the number of dispensed notes
and the status of notes.
2. Check CS13(NS4).
3. Check logic related to CS13(NS4) of
the Cash Dispenser Unit board.
1. Check Main motor
2. Check Cash Dispnser Unit Main
board
1. Check the note-setting status in the
cassette.
2. Check CS1A and 1B(NS2) sensors.
1. Check CS2,CS4 and CS13(NS3/NS4)
2. Check Cassette
The Control Electronics revises and
reissues the command.
Check if there are notes in the return
path.
If so, remove them.
1. Check the status of the note.
2. Check if the note type on the index
set by the Control Electronics matches
with the actual note type.
1. Check the number of dispensed
notes.
2. Check if the gate normally functions.
1. Check if the cassette has been
normally installed.