1. Place charger and machine in a well ventilated
area.
2. Turn the machine off.
3. If charging wet (lead acid) batteries check the
fluid level before charging.
4. Connect the charger's AC power supply cord to
a properly grounded receptable.
5. Connect the charger's DC cord into the
machine's battery receptacle at the rear of the
machine.
6. Prop up the recovery tank by the support
stand (see machine components, item #30) for
ventilation when charging.
7. The charger will automatically begin to charge
and will autoatically shut off once the batteries
are fully charged.
8. Upon completion of charging, disconnect the
AC power supply cord first, and then disconnect
the charger from the machine.

PREVENTATIVE MAINTENANCE

WARNING: Before performing any
maintenance on the machine, be sure that
the power is turned off, or the batteries are
disconnected!
WARING: Repairs are to be completed
by Authorized service centers only. Any repairs
completed by unauthorized persons will avoid
the warrenty.
DAILY MAINTENANCE
1. Remove pad driver/ brush and clean with
approved cleaner.
2. Drain recovery and solution tanks completely
and rinse out with clean water. Visually check
the recovery tank for debris and clean out as
necessary.
3. Raise the squeegee assembly off floor and wipe
it down with a damp towel. Be sure to store the
squeegee in the up position.
4. Remove the float shut-off assembly and rinse it
out with clean water.
5. Clean machine with an approved cleaner and a
damp towel.
6. Recharge the batteries.
7. Check the condition of the squeegee blade
wiping edge, rotate blade if worn.
ICE i20NB / i20NBT / i20NBT-OB / i24BT
MONTHLY MAINTENANCE
1. Clean the battery tops to prevent corrosion.
2. Check for loose battery cable connections.
3. Inspect and clean the recovery tank cover seal.
Replce it if damaged.
4. Lubricate all grease points and pivot points with
silicon spray and approved grease.
5. Check the machine for loose nuts and bolts.
6. Check the machine for leaks.
MOTOR MAINTENANCE
1. Contact your local Distributor for any motor
maintenance.
2. Motor should have the brushes checked every
250 hours. Brushes should be replaced when
they are worn to a length of 10 mm or less.
ORBITAL HEAD MAINTENANCE
For Orbital head, you should have checked the
eight isolators located in the Orbital head every
300 hours.
1. Using a flashlight, do a visual inspection of the
isolators by looking throught the opening in the
Orbital head and checking for wear or damage
to four isolators in the front and four in the
rear of the Orbital head. The locations of the
isolators are show below.
2. If any of the eight isolators show signs of wear,
degradation or damage, contact your lacal
distributor to replace all eight isolators.