DEC 7000 AXP Operation Manual page 39

Hide thumbs Also See for 7000 AXP:
Table of Contents

Advertisement

XMI PIUs
A maximum of two XMI PIUs can be installed in the system cabinet. Each
XMI PIU has 14 slots. Twelve slots can contain the following modules:
CIXCD, DEMFA, DEMNA, KDM70, KFMSA (for VAX 7000 systems), and
KZMSA (for DEC 7000 systems). One module must be installed in slots 1
or 14. Slot 7 contains the clock module, and slot 8 contains the DWLMA
module.
SCSI PIU
Up to two SCSI PIUs can be installed in the DEC 7000 system
DEC
cabinet (along with the XMI PIU). A SCSI PIU can have two
7000
shelves. Each shelf holds up to seven SCSI disks or tapes: RZ26,
RZ73, and TLZ06.
DSSI PIU
Up to two DSSI PIUs can be installed in the VAX 7000 system
VAX
cabinet (along with the XMI PIU). A DSSI PIU contains up to
7000
three storage array building blocks (SABB). Each SABB can con-
tain two RF73 disks.
Battery PIUs
The system can be equipped with an optional battery PIU to provide unin-
terrupted power in case of a power failure. Each regulator requires a bat-
tery pack that is mounted in the bottom of the system cabinet. The battery
PIUs provide a minimum of 8 minutes of full system operation when fully
charged and nominally provide 11 minutes of full system operation.
In-Cabinet Tape Drive
A TLZ06 tape drive can be installed in the SCSI PIU in the DEC 7000 sys-
tem cabinet. A TF85 tape drive can be installed in the VAX 7000 system
cabinet. The tape drive can be used as a backup storage device or as an I/O
device for user applications.
System Components 2-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vax 7000

Table of Contents