Maintenance
When you are done replacing the rollers, close the scanner carefully pressing down on both sides
of the cover until it locks in place. Do not slam down the cover.

Replacing the Feed Roller Module

The roller will wear out and is designed to be a user-replaceable part. A worn roller can cause
documents to feed in skewed at an angle, or multiple pages to feed at the same time. Before
replacing the roller you should clean it as excessive dust on the roller will make it appear worn and
smooth. You cannot properly diagnose a worn roller until you have cleaned it. You should generally
replace the roller every 350,000 pages.
1.
Pull the locking lever on the left side of the feed roller module down from the scanner. This
releases the roller module from the scanner.
2.
Carefully remove the roller module from the scanner. Discard the roller module, it cannot be
repaired or reused.
3.
Take the new roller module out of its packaging.
4.
Align the end of the plastic end on the right side of the roller module with the slot in the roller
compartment. Make sure the flat side of the roller tip is aligned properly with the slot in the
scanner.