Connection diagrams

• The drawings are not intended to describe a complete system. It is up to the certified service technician to determine
the necessary components for and configuration of the particular system being installed (for example, an additional
surge protector).
• The drawings do not imply compliance with state or local code requirements or regulations. It is the certified service
technician's responsibility to make sure that the installation is fully compliant with all state or local code requirements
or regulations.
AquaGo comfort
Top
Hot Water
Outlet
Instant
Water Heater
Cold Water
Inlet
Gas side connection
Fig. 17
AquaGo comfort plus
Top
Hot Water
Outlet
Instant
Circulation
Water Heater
Line Inlet
Gas side connection
Fig. 18
Electrical connection for all models
Maximum length of the power supply cable (including cables for the optional switch):
• for 16 AWG or 1.5 mm² MWG: max. 12 m (bidirectional)
• for 14 AWG or 2.0 mm² MWG: max. 20 m (bidirectional)
Instant
Water Heater
Fig. 19
22
A*
C*
B*
Gas rear connection
A*
E*
C*
D*
B*
Cold Water
Inlet
Drain Line
Gas rear connection
Optional:
Switch ON - OFF
(Rating: ≥ 7.5 A)
+
-
Tap 1
Tap 2
* Bypass kit for winterising (not in scope of delivery)
Maximum pressure 450 kPa
LP gas supply (propane only)
Inlet pressure 2.62 - 3.49 kPa
Tap 1
Tap 2
* Bypass kit for winterising (not in scope of delivery)
Maximum pressure 450 kPA
LP gas supply (propane only)
Inlet pressure 2.62 - 3.49 kPa
+
12 VDC
Ripple < 1 V
pp
-
Control
panel /
Diagnosis
Shower
Shower
12 VDC
7.5 A
Power
Supply