Intended use .......................................................................... 3
Functional description .......................................................... 3
Scope of delivery ................................................................... 3
Safety instructions ................................................................ 4
Operating instructions .......................................................... 7
Decalcification frequency ......................................................... 7
Preparing for decalcification .................................................... 8
Connecting the circulation pump ............................................. 8
Carrying out the decalcification process ............................... 10
Cleaning the circulation pump .............................................. 10
Flushing the water system ..................................................... 11
Stopping decalcification ......................................................... 11
Accessories .......................................................................... 11
Technical data, pump ......................................................... 11
Troubleshooting .................................................................. 12
MANUFACTURER LIMITED WARRANTY ........................ 13

Advertisement

Table of Contents
loading

Summary of Contents for Truma AquaGo

  • Page 1: Table Of Contents

    ® Professional decalcification kit for Truma AquaGo Table of contents Intended use ................3 Functional description ............3 Scope of delivery ..............3 Safety instructions ..............4 Operating instructions ............7 Decalcification frequency ............7 Preparing for decalcification ............ 8 Connecting the circulation pump ..........
  • Page 2 Overview Legend 1 Easy Drain Lever 5 Plug 2 Outlet hose 6 POWER switch 3 Inlet hose 7 Control panel 4 Socket (12 pin) 8 Connector cable ( circulation pump) Circulation adapter Figure 1 Figure 2...
  • Page 3: Intended Use

    Circulation pump Functional description The Professional decalcification kit for AquaGo pumps a decalcification solution through the AquaGo instant water heater with the aid of a circulation pump. This dissolves and flushes out calcium residues. Scope of delivery Figure 3 • Service case •...
  • Page 4: Safety Instructions

    Other important information or tips The operating instructions supplied with the Installation and service must be performed AquaGo instant water heater are part of these by an expert. Improper installation, altera- operating instructions for the Professional de- calcification kit for AquaGo.
  • Page 5 11). – damage to your AquaGo, – and the voiding of your warranty. – Call your local AquaGo dealer or service provider or see www.truma.net for more information to obtain AquaGo profes- Danger of crushing/pinching of fingers sional decalcification.
  • Page 6 For more information see “Winter face protection to avoid contact. operation” in the operating instructions for the AquaGo instant water heater. • Never use the water supply in the RV dur- ing decalcification. • In case of skin contact with the decalcifica- tion agent, immediately rinse the affected area with plenty of water.
  • Page 7: Operating Instructions

    Decalcification frequency Usage* normal high Lime scale occurs especially as a result of pre- cipitation from “hard” water. The AquaGo must * Hot water consumption (approximately) be decalcified regularly depending on water 635 gallon/year 2400 l/year hardness and hot water consumption.
  • Page 8: Preparing For Decalcification

    1.3 gallons (5 l) of drinking water. (Duration Latch approx. 10 min.). • Open the access door of the AquaGo. (See “Opening the access door” in the op- erating instructions for the AquaGo instant water heater.) •...
  • Page 9 If the O-rings are damaged or • Place the circulation pump (10) and outlet missing, the decalcification solution may hose (2) in the bucket with the decalcifica- leak during the decalcification process. tion solution. (see Figure 6) Before inserting the circulation adapter (9), check that the O-rings are in place and intact (see Figure 2, page 2).
  • Page 10: Carrying Out The Decalcification Process

    • Place the circulation pump (10) and the out- • Remove the socket (4) from the control pan- let hose (2) in a bucket with drinking water. el (7) of the AquaGo and connect it with the • Connect the socket (4) and the plug (5). plug (5).
  • Page 11: Flushing The Water System

    (part no. 77000-00130) • Plug the socket (4) on to the control panel (7) Technical data, pump of the AquaGo and switch it on at the POWER switch (6). • Close the access door of the AquaGo. Operating voltage (See “Closing the access door”...
  • Page 12: Troubleshooting

    Troubleshooting Problem Potential cause Resolution Circulation pump not working No/insufficient power supply Check and/or establish a power supply Circulation pump defective Check and/or replace circulation pump Water leaking at O-ring dirty Clean O-ring and corresponding circulation adapter surface with clean water O-ring damaged/missing Check and/or replace O-ring...
  • Page 13: Manufacturer Limited Warranty

    WARRANTY ranty defect. Costs of diagnosis for a warranty (September 2014) defect are borne by TRUMA. Other costs of di- This limited warranty pertains solely to the agnosis are not included in this warranty. At the “Professional decalcification kit for AquaGo”...
  • Page 14 This limited warranty does not cover any defects The purchaser shall provide the following attributable in whole or in part to (i) non-TRUMA information regarding the potential warranty products and services and / or alterations of claim (i) serial number of the defective device, out-of-specification supplies, (ii) accidents, mis- (ii) proof of purchase, (iii) purchaser’s contact...
  • Page 15 TRUMA knew or should have known of the pos- sibility of such losses or damages, (b) claims, demands or actions against the customer by any person, except as provided by applicable law.
  • Page 16 In case you encounter any problems, Please have the model number and serial please contact the Truma Service Center number (on water heater’s type plate) handy at 855-558-7862 or one of our autho- when you call. rized service partners. For details see...