Connecting to the RS-232C Port at the Host
86
S Connecting to CS1 series serial communication unit
A CS1 series backplane mounted type : CS1W-SCU21
[Setting the front switches]
Set the unit number of the serial communication unit by using the rotary switch lo-
cated on the front panel. Set each switch with a flat blade screwdriver so that the
values or symbols in the setting value window agree with the following.
SCU21
RUN
RDY
ERC
ERH
SD1
SD2
RD1
RD2
UNIT
F E
1 0
No.
D
3 2
C
5 4
B A
7 6
9 8
[Allocation DM area settings for CPU]
Setting is written from the peripheral tool (a programming console or CX-Program-
mer) directly into the allocation DM area (system setting area) of the CPU. After
the setting is written, it becomes effective by turning the power ON, restarting the
unit, restarting the communication port, or execution of the STUP command.
In the following, the channel numbers of the allocation DM area and settings are
shown.
Allocation DM
area
H)
Port 1
Port 2
m
m+10
m+6
m+16
Set the unit number to "0" through "F" so
that it will not overlap with the numbers
used in other units.
Writing Value
8200
000
E
-
m=DM30000+100*unit number (CH)
Settings
NT link (1:N) mode
model number of the connected PT (0 – 7)
Section 4-1